Suppr超能文献

猫脉冲近红外激光小梁成形术后小梁网改变及眼压变化

Trabecular meshwork alteration and intraocular pressure change following pulsed near-infrared laser trabeculoplasty in cats.

作者信息

Stoiber Josef, Fernandez Viviana, Lamar Peggy D, Decker Susan J, Dubovy Sander, Hitzl Wolfgang, Salas Nelson, Fantes Francisco, Parel Jean-Marie

机构信息

Bascom Palmer Eye Institute, Ophthalmic Biophysics Center, University of Miami Miller School of Medicine, Miami, Florida 33136, USA.

出版信息

Ophthalmic Surg Lasers Imaging. 2005 Nov-Dec;36(6):471-81.

Abstract

BACKGROUND AND OBJECTIVE

To comparatively assess the safety and variation in intraocular pressure (IOP) of two pulsed near-infrared lasers (titanium:sapphire and alexandrite) for laser trabeculoplasty versus conventional blue-green argon laser trabeculoplasty in an animal model.

MATERIALS AND METHODS

The left eyes of 15 healthy cats received a 180 degree laser trabeculoplasty treatment: 5 with a titanium:sapphire laser, 5 with an alexandrite laser, and 5 with an argon laser. Preoperatively and postoperatively, all animals underwent tonometry, gonioscopy, and slit-lamp examination. The cats were observed up to 12 weeks. Scanning electron microscopy and histologic examination were performed to evaluate potential alterations in the trabecular meshwork structure.

RESULTS

IOP at 1 hour, 1 day, and 1 week following treatment was remarkably lower, irrespective of the laser source used. Following treatment with both near-infrared lasers, gonioscopy showed depigmentation underneath the area of the treated trabecular meshwork and histologic evaluation showed a decrease in pigment density. On scanning electron microscopy, damage to the trabecular meshwork structure could not be detected after treatment with near-infrared lasers.

CONCLUSIONS

Near-infrared laser trabeculoplasty was found to be effective to temporarily lower IOP in cats. The lasers selectively altered pigment-containing cells, avoiding structural damage of the trabecular meshwork anatomy.

摘要

背景与目的

在动物模型中,比较评估两种脉冲近红外激光(钛宝石激光和翠绿宝石激光)与传统蓝绿氩激光小梁成形术在眼压(IOP)方面的安全性和变化情况。

材料与方法

15只健康猫的左眼接受180度激光小梁成形术治疗:5只接受钛宝石激光治疗,5只接受翠绿宝石激光治疗,5只接受氩激光治疗。术前和术后,所有动物均接受眼压测量、前房角镜检查和裂隙灯检查。对猫进行长达12周的观察。进行扫描电子显微镜检查和组织学检查,以评估小梁网结构的潜在改变。

结果

无论使用何种激光源,治疗后1小时、1天和1周时的眼压均显著降低。在用两种近红外激光治疗后,前房角镜检查显示治疗的小梁网区域下方色素脱失,组织学评估显示色素密度降低。在扫描电子显微镜下,近红外激光治疗后未检测到小梁网结构受损。

结论

发现近红外激光小梁成形术可有效暂时降低猫的眼压。这些激光选择性地改变含色素细胞,避免小梁网解剖结构的损伤。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验