In 2002, Ochsner laparoscopic surgeons and nephrologists began placing peritoneal dialysis (PD) catheters via a laparoscopic-assisted method. We compared laparoscopically placed PD catheters (LAPD) with catheters most recently placed without laparoscopic aid (STPD). The method for this study is a retrospective chart review. Demographics of both groups were similar. Nine of 20 (45%) in the STPD group and 16 of 23 (70%) in the LAPD group had had previous abdominal surgery. Three of 20 (15%) of STPD had complications, including one small bowel injury. Four of 23 (17.4%) of the LAPD had complications. One of 20 (5%) in the STPD group and 3 of 23 (13%) in the LAPD group had dialysate leaks. In the STPD group, 8 of 20 (40%) had catheter problems that led to removal in 7 (35%). In the LAPD group, 6 of 23 (26%) had catheter malfunction: 3 were salvaged with a laparoscopic procedure; 3 (13%) were removed for malfunction. 1) LAPD allows proper PD placement after complex abdominal surgery; 2) Although dialysate leak complications are increased, bowel perforation risk is less; 3) Because of proper placement, PD catheter malfunction rate is less with LAPD; 4) Although no results obtained statistical significance, we found LAPD superior to STPD and have converted to this technique.

摘要

2002年,奥施纳的腹腔镜外科医生和肾病学家开始通过腹腔镜辅助方法置入腹膜透析(PD)导管。我们将腹腔镜置入的PD导管(LAPD)与最近在无腹腔镜辅助情况下置入的导管(STPD)进行了比较。本研究方法为回顾性病历审查。两组的人口统计学特征相似。STPD组20例中有9例(45%)、LAPD组23例中有16例(70%)曾接受过腹部手术。STPD组20例中有3例(15%)出现并发症,包括1例小肠损伤。LAPD组23例中有4例(17.4%)出现并发症。STPD组20例中有1例(5%)、LAPD组23例中有3例(13%)出现透析液渗漏。在STPD组,20例中有8例(40%)出现导管问题,其中7例(35%)导管被拔除。在LAPD组,23例中有6例(26%)出现导管故障:3例通过腹腔镜手术挽救;3例(13%)因故障被拔除。1)LAPD可在复杂腹部手术后实现PD导管的正确置入;2)虽然透析液渗漏并发症有所增加,但肠穿孔风险较低;3)由于置入正确,LAPD的PD导管故障率较低;4)虽然结果未获得统计学显著性,但我们发现LAPD优于STPD,并已改用该技术。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验