Oakey Jerome W, Stover Michael D, Summers Hobie D, Sartori Mark, Havey Robert M, Patwardhan Avinash G
Loyola University Medical Center, Maywood, IL 60153, USA.
Clin Orthop Relat Res. 2006 Feb;443:302-6. doi: 10.1097/01.blo.0000188557.65387.fc.
A subtrochanteric femur fracture after cannulated screw fixation of a femoral neck fracture is a devastating complication. We hypothesized that an apex-distal screw orientation would tolerate higher loads to subtrochanteric fracture. Human cadaveric femora were instrumented with three cannulated screws in either an apex-distal or an apex-proximal configuration. Specimens were loaded along the mechanical axis to failure creating a subtrochanteric femur fracture. Ultimate load to failure and the effect of bone density on load to failure were compared between groups. There was a greater load to failure in the apex-distal group compared with the apex-proximal group. The mean force to fracture in the apex-distal group (11,330 N; standard deviation = 3151 N) was greater than the mean force to fracture in the apex-proximal group (7795 N; standard deviation = 3194 N). Previous investigations have shown improved femoral neck fixation with an apex-distal configuration, but none has examined the relationship between screw orientation and subtrochanteric fractures. Our observations support the use of an apex-distal configuration for cannulated screw fixation of femoral neck fractures.
股骨颈骨折空心钉固定术后发生股骨转子下骨折是一种严重的并发症。我们推测,尖 - 远侧螺钉方向能够承受更高的导致转子下骨折的负荷。对人体尸体股骨分别采用尖 - 远侧或尖 - 近侧构型植入三根空心钉。沿力学轴线对标本加载直至破坏,造成股骨转子下骨折。比较两组之间的极限破坏负荷以及骨密度对破坏负荷的影响。与尖 - 近侧组相比,尖 - 远侧组的破坏负荷更大。尖 - 远侧组的平均骨折力(11330 N;标准差 = 3151 N)大于尖 - 近侧组的平均骨折力(7795 N;标准差 = 3194 N)。先前的研究表明,尖 - 远侧构型可改善股骨颈固定,但尚无研究探讨螺钉方向与转子下骨折之间的关系。我们的观察结果支持采用尖 - 远侧构型进行股骨颈骨折的空心钉固定。