Suppr超能文献

Diagnostic accuracy of contrast-enhanced ultrasound in focal lesions of the liver using cadence contrast pulse sequencing.

作者信息

Bleuzen A, Huang C, Olar M, Tchuenbou J, Tranquart F

机构信息

Centre Innovations Technologiques, CHRU Tours, 37044 Tours Cédex 1, Frankreich.

出版信息

Ultraschall Med. 2006 Feb;27(1):40-8. doi: 10.1055/s-2005-858944.

Abstract

UNLABELLED

The purpose of this study was to assess the accuracy of Cadence Contrast Pulse Sequencing (Siemens-Acuson, CA) method with injection of SonoVue (Bracco Imaging SpA, Italy) for the detection and characterisation of focal liver lesions in comparison with a reference modality during routine use.

METHODS

138 consecutive patients (62 women, 76 men; mean age: 52 years for women and 63 years for men) corresponding to 144 examinations with 381 lesions participated in this prospective study from December 2002 to November 2003. Inclusion criteria were lesions detected by conventional US and the availability of a reference imaging examination (CT or MR imaging) within three weeks. The underlying liver lesions characterised by a reference modality (including biopsy in 29 lesions) were distributed as follows: haemangioma (n = 56), focal nodular hyperplasia (n = 27), hepatocellular carcinoma (n = 44), hepatocellular adenoma (n = 5), liver metastasis (n = 174), abscess (n = 2), cysts (n = 45), other benign lesions (n = 24) and 3 peritoneal metastases.

RESULTS

A significant improvement was reported in the number of detected lesions between contrast-enhanced ultrasound and baseline ultrasonography (351 lesions versus 280 lesions, respectively, p < 0.01), whereas no significant difference was noted between contrast-enhanced ultrasound and reference imaging (351 versus 377 lesions, respectively). On the whole, contrast-enhanced ultrasound allowed a complete diagnosis in 96 % of the detected nodules with a significant improvement compared to conventional sonography in which the diagnosis was suspected in only 52 % out of these cases (p < 0.001). No significant difference was noted between contrast-enhanced ultrasound and the reference modality concerning characterisation of nodules.

CONCLUSION

The present study clearly indicates that contrast-enhanced sonography using Sonovue and Cadence Contrast Pulse Sequencing allows real-time imaging with high accuracy and thus will be a competitive alternative to other modalities such as CT and MR imaging for liver imaging.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验