Contrast-enhanced ultrasound with SonoVue: differentiation between benign and malignant focal liver lesions in 317 patients.

作者信息

von Herbay Alexandra, Westendorff Julia, Gregor Michael

机构信息

University of Tübingen, Department of Medicine, Otfried-Müller-Str. 10, D-72076 Tübingen, Germany.

出版信息

J Clin Ultrasound. 2010 Jan;38(1):1-9. doi: 10.1002/jcu.20626.

Abstract

PURPOSE

The aim of the study was to investigate the ability of contrast-enhanced sonography (CEUS) with the contrast agent SonoVue to differentiate between benign and malignant focal liver lesions.

METHODS

In a prospective study, we examined 317 patients (204 males, 113 females, aged 59 +/- 12 years) with focal liver lesions detected by B-mode gray-scale sonography. After intravenous injection of 1.2 mL SonoVue, the liver was examined continuously for 3 minutes using low-MI sonography with contrast-specific software. Final diagnosis was established by histopathology, CT, MRI, or HIDA-scintigraphy.

RESULTS

Two hundred nine patients had malignant focal lesions, including 107 hepatocellular carcinomas, 70 metastases, 26 cholangiocellular carcinomas, and 6 other types of malignancy. One hundred eight patients had benign focal lesions, including 30 regenerative nodules, 30 hemangiomas, 13 cases of focal nodular hyperplasia, 12 abscesses, 8 cases of necrosis, 7 cases of focal steatosis areas, and 8 other benign lesions. Hypoenhancement or no enhancement in the late phase was found in 91% of the malignant lesions but in only 37% of the benign lesions (p < 0.001, sensitivity = 64%, specificity = 93%). Hyperenhancement in the late phase was found in 20% of the benign lesions but in none of the malignant lesions (p < 0.001, sensitivity = 21%, specificity = 100%). Hyperenhancement in the early phase with diffuse complete enhancement was found in 30% of the patients with malignant lesions but in only 2% of the patients with benign lesions (p < 0.001, sensitivity = 30%, specificity = 98%). CEUS had a sensitivity of 90%, a specificity of 99%, and an accuracy of 89% in the diagnosis of malignant liver lesions.

CONCLUSION

CEUS is helpful in the differentiation between benign and malignant focal liver lesions.

摘要

目的

本研究旨在探讨使用造影剂声诺维的超声造影(CEUS)鉴别肝脏局灶性病变良恶性的能力。

方法

在一项前瞻性研究中,我们检查了317例经B型灰阶超声检测出肝脏局灶性病变的患者(男性204例,女性113例,年龄59±12岁)。静脉注射1.2 mL声诺维后,使用具有造影剂特异性软件的低机械指数超声对肝脏连续检查3分钟。最终诊断通过组织病理学、CT、MRI或HIDA闪烁扫描确定。

结果

209例患者有恶性局灶性病变,包括107例肝细胞癌、70例转移瘤、26例胆管细胞癌和6例其他类型恶性肿瘤。108例患者有良性局灶性病变,包括30例再生结节、30例血管瘤、13例局灶性结节性增生、12例脓肿、8例坏死、7例局灶性脂肪变性区域和8例其他良性病变。91%的恶性病变在延迟期表现为低增强或无增强,而良性病变仅为37%(p<0.001,敏感性=64%,特异性=93%)。20%的良性病变在延迟期表现为高增强,而恶性病变均无此表现(p<0.001,敏感性=21%,特异性=100%)。30%的恶性病变患者在早期表现为高增强且呈弥漫性完全增强,而良性病变患者仅为2%(p<0.001,敏感性=30%,特异性=98%)。CEUS诊断恶性肝脏病变的敏感性为90%,特异性为99%,准确性为89%。

结论

CEUS有助于鉴别肝脏局灶性病变的良恶性。