Suppr超能文献

具有固有射线不透性的含碘聚乙烯醇作为液体栓塞剂:在实验性宽颈动脉瘤中的评估

Intrinsically radiopaque iodine-containing polyvinyl alcohol as a liquid embolic agent: evaluation in experimental wide-necked aneurysms.

作者信息

Dudeck Oliver, Jordan Olivier, Hoffmann Karl-Titus, Tesmer Kai, Kreuzer-Nagy Tibor, Podrabsky Petr, Heise Michael, Meyer Rudolf, Okuducu Ali Fuat, Bruhn Harald, Hilborn Jöns, Rüfenacht Daniel A, Doelker Eric, Felix Roland

机构信息

Department of Radiology, Charité, Campus Virchow Clinic, Berlin, Germany.

出版信息

J Neurosurg. 2006 Feb;104(2):290-7. doi: 10.3171/jns.2006.104.2.290.

Abstract

OBJECT

To evaluate iodine-containing polyvinyl alcohol (I-PVA) as a precipitating liquid embolic agent, implant characteristics--including radiopacity, setting behavior, and biocompatibility--were studied in an aneurysm model in swine.

METHODS

Twelve broad-based carotid artery (CA) sidewall aneurysms were surgically constructed in six pigs. Iodine-containing polyvinyl alcohol dissolved in dimethyl sulfoxide (DMSO) was injected during temporary balloon occlusion bridging the aneurysm neck. Control angiography as well as multidetector row computerized tomography (CT) angiography was performed after 4 weeks. Harvested aneurysms were investigated histopathologically and by 3-tesla high-field magnetic resonance (MR) imaging. The mean degree of aneurysm occlusion achieved was 96%. In two aneurysms a minimal protrusion of I-PVA into the CA lumen was observed. During one embolization, leakage of the liquid embolic agent due to DMSO-induced damage of the microcatheter resulted in CA occlusion. Aneurysms embolized with I-PVA could be discriminated clearly from the parent artery on CT angiograms because there was no beam-hardening artifact. High-field MR imaging allowed a detailed depiction of the liquid embolic distribution within the aneurysm. Histologically, a mild to moderate inflammatory response was found in successfully embolized aneurysms, and the polymer mass was frequently covered by a membrane of fibroblasts and endothelial cells.

CONCLUSIONS

Iodine-containing polyvinyl alcohol is a ready-to-use liquid embolic agent clearly visible under fluoroscopy; additives are not required. The setting behavior allows for controlled delivery in aneurysm cavities. Histological studies performed 4 weeks after embolization revealed no sign of toxic tissue response to the liquid embolic agent. Overall, I-PVA exhibits interesting implant characteristics in that radiopaque admixtures are not necessary, thus allowing for artifact-free evaluation of treated aneurysms by using CT and MR angiography.

摘要

目的

为评估含碘聚乙烯醇(I-PVA)作为一种沉淀性液体栓塞剂,在猪动脉瘤模型中研究了其植入特性,包括显影性、凝固行为和生物相容性。

方法

在6头猪身上通过手术构建了12个宽颈颈动脉(CA)侧壁动脉瘤。在临时球囊阻断跨越动脉瘤颈部期间,注入溶解于二甲基亚砜(DMSO)的含碘聚乙烯醇。4周后进行对照血管造影以及多排螺旋计算机断层扫描(CT)血管造影。对收获的动脉瘤进行组织病理学检查和3特斯拉高场磁共振(MR)成像。实现的动脉瘤闭塞平均程度为96%。在两个动脉瘤中观察到I-PVA有最小程度地突入CA管腔。在一次栓塞过程中,由于DMSO导致微导管损伤,液体栓塞剂泄漏导致CA闭塞。在CT血管造影上,用I-PVA栓塞的动脉瘤可与母动脉清晰区分,因为没有线束硬化伪影。高场MR成像能够详细描绘动脉瘤内液体栓塞剂的分布。组织学上,在成功栓塞的动脉瘤中发现轻度至中度炎症反应,聚合物团块常被成纤维细胞和内皮细胞膜覆盖。

结论

含碘聚乙烯醇是一种在荧光透视下清晰可见的即用型液体栓塞剂;无需添加物。其凝固行为允许在动脉瘤腔内进行可控注射。栓塞后4周进行的组织学研究未显示对液体栓塞剂有有毒组织反应的迹象。总体而言,I-PVA表现出有趣的植入特性,即无需不透射线的混合物,从而允许通过CT和MR血管造影对治疗的动脉瘤进行无伪影评估。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验