Human fibrin sealant (FS) has been proven effective for skin grafting after severe burn, however no systematic evaluation of application conditions has been performed so far. In order to find the optimal FS amount for fixation of skin grafts to deep defects, we created four full thickness wounds (8 cmx4 cm) on the dorsum of six male pigs. Wounds were covered with unmeshed split thickness skin grafts and fixed either with a thin layer (0.05 ml/cm2) or a thick layer (0.15 ml/cm2) of fibrin sealant (FS) without additional sutures. Sutures served as controls. FS was used as a slow clotting spray (4-5 IUthrombin/ml). Outcome measurements revealed that hematoma formation (day of surgery) was more extensive and occurred more frequently in the suture group as compared to FS 0.05 ml/cm2 (p<0.05). Areas of graft dislocation tended to be larger in the suture group versus the FS 0.05 ml/cm2. The FS 0.05 ml/cm2 graft take on day 5 appeared to be enhanced in comparison to the suture group. Excellent outcome was notable on the final observation day (day 21) in the FS 0.05 ml/cm2 group with a take of 99.7% (IQR 96.1-100%). Corresponding values in the FS 0.15 ml/cm2 group were 96.9% (IQR 92.2-99%) and 95.9% (IQR 93.2-98%) in the suture group. The results indicate, that the usage of a sprayed thin FS layer (0.05 ml/cm2) in a slow clotting rate (4-5 IUthrombin/ml) is an appropriate fixation method in split thickness skin transplantation.
人纤维蛋白密封剂(FS)已被证明在严重烧伤后的皮肤移植中有效,但迄今为止尚未对其应用条件进行系统评估。为了找到将皮肤移植物固定到深部缺损的最佳FS用量,我们在六只雄性猪的背部创建了四个全层伤口(8 cm×4 cm)。伤口覆盖非网状的断层皮片,并用薄层(0.05 ml/cm²)或厚层(0.15 ml/cm²)的纤维蛋白密封剂(FS)固定,无需额外缝合。缝合作为对照。FS用作慢凝喷雾(4 - 5 IU凝血酶/ml)。结果测量显示,与FS 0.05 ml/cm²组相比,缝合组在手术当天血肿形成更广泛且更频繁发生(p<0.05)。缝合组的移植物脱位面积往往比FS 0.05 ml/cm²组更大。与缝合组相比,FS 0.05 ml/cm²组在第5天的移植物存活情况似乎更好。在最终观察日(第21天),FS 0.05 ml/cm²组效果极佳,移植物存活率为99.7%(四分位间距96.1 - 100%)。FS 0.15 ml/cm²组的相应值为96.9%(四分位间距92.2 - 99%),缝合组为95.9%(四分位间距93.2 - 98%)。结果表明,在断层皮片移植中,使用慢凝率(4 - 5 IU凝血酶/ml)的喷雾薄层FS(0.05 ml/cm²)是一种合适的固定方法。