Suppr超能文献

Multidirectional flexibility analysis of anterior and posterior lumbar artificial disc reconstruction: in vitro human cadaveric spine model.

作者信息

Kotani Yoshihisa, Cunningham Bryan W, Abumi Kuniyoshi, Dmitriev Anton E, Hu Niabin, Ito Manabu, Shikinami Yasuo, McAfee Paul C, Minami Akio

机构信息

Department of Orthopaedic Surgery, Hokkaido University Graduate School of Medicine, Kita-15, Nishi-7, Sapporo 060-8638, Japan.

出版信息

Eur Spine J. 2006 Oct;15(10):1511-20. doi: 10.1007/s00586-006-0086-z. Epub 2006 Mar 22.

Abstract

The in vitro multidirectional flexibility analysis was conducted to investigate the initial biomechanical effect of biomimetic artificial intervertebral disc replacement from either anterior or posterior approach in a cadaveric lumbosacral spine model. Two designs of anterior total and posterior subtotal artificial discs were developed using bioactive three-dimensional fabric and bioresorbable hydroxyapatite/poly-l-lactide material (3DF disc). Both models were designed to obtain the stable interface bonding to vertebral endplates with maximum surface area occupation. Using seven cadaveric lumbosacral spines, the following three anterior reconstruction methods were sequentially performed at L4-5 level: anterior 3DF disc replacement; anterior BAK cages (BAK); and posterior pedicle screw fixation and anterior BAK cages combined (BAK + PS). The L2-3 level received two methods of posterior reconstructions: subtotal 3DF disc replacement (two implants), and posterior interbody cages and pedicle screw fixation (PLIF). Six unconstrained pure moments were applied and three-dimensional segmental motions were measured with an optoelectronic motion measurement system. The center of rotation (COR) calculation was conducted radiographically using flexion-extension films. Both anterior and posterior 3DF replacements statistically demonstrated equivalent range of motions (ROMs) in all loading modes compared to intact segment. Anterior BAK, BAK + PS, and PLIF demonstrated significantly lower ROMs when compared to intact and 3DF groups (P<0.05). The 3DF reconstruction tended to realign the COR to the posterior third or surrounding position at the operative disc level. The stand-alone lumbar 3DF disc replacement demonstrated biomechanical characteristics nearly equivalent to the intact spinal segments even through anterior or posterior approach in vitro, suggesting an excellent clinical potential.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验