Suppr超能文献

Sonographic evaluation of gallbladder kinetics: in vitro and in vivo comparison of different methods to assess gallbladder emptying.

作者信息

Wedmann B, Schmidt G, Wegener M, Coenen C, Ricken D, Dröge C

机构信息

Department of Medicine, St. Josef Hospital, Ruhr University, Federal Republic of Germany.

出版信息

J Clin Ultrasound. 1991 Jul-Aug;19(6):341-9. doi: 10.1002/jcu.1870190604.

Abstract

In an in vitro study, 10 gallbladders of adult pigs and 6 gallbladders of lambs, all removed immediately after slaughtering, were stimulated in a water bath by electric means to induce active contraction. Gallbladder emptying was followed by ultrasonography employing five measurement procedures: (1) gallbladder width, (2) longitudinal planimetry, (3) transverse planimetry, (4) ellipsoid method, and (5) sum of cylinders method. In an in vivo investigation, gallbladder emptying of 30 volunteers (12 healthy subjects, 18 diabetics) was evaluated in the same way after ingestion of a fatty meal. Gallbladder width was found to be unsuitable to estimate the decrease in gallbladder volume due to a nonlinear relation of the parameters. Longitudinal planimetry tended to be less valid than transverse planimetry in assessing gallbladder volume reduction. The most valid estimation of gallbladder volume decreases was obtained by the two three-dimensional procedures. However, in neither in vitro nor in vivo could a significant difference between the sum of cylinders method and the ellipsoid method in determining relative volume reduction be established. We conclude that a three-dimensional measurement procedure should be used for valid assessments of gallbladder motility. However, according to our data there is no advantage in using the time-consuming sum of cylinders method compared to the simple ellipsoid method.

摘要

相似文献

3
Evaluation of gallbladder volume and emptying with a novel three-dimensional ultrasound system: comparison with the sum-of-cylinders and the ellipsoid methods.
J Clin Ultrasound. 1996 Jul-Aug;24(6):277-85. doi: 10.1002/(SICI)1097-0096(199607/08)24:6<277::AID-JCU1>3.0.CO;2-F.
4
An evaluation of three-dimensional ultrasonography for the measurement of gallbladder volume.
Am J Gastroenterol. 1999 Dec;94(12):3492-6. doi: 10.1111/j.1572-0241.1999.01612.x.
5
Sonographic measurement of gallbladder volume.
AJR Am J Roentgenol. 1985 Nov;145(5):1009-11. doi: 10.2214/ajr.145.5.1009.
7
In vitro and in vivo accuracy of sonographic gallbladder volume determinations.
J Clin Ultrasound. 1993 Mar-Apr;21(3):157-62. doi: 10.1002/jcu.1870210302.
9
Variability of gallbladder emptying after oral stimulation.
Scand J Gastroenterol. 1997 Jul;32(7):719-24. doi: 10.3109/00365529708996524.
10
Variation in the estimation of gallbladder volume using the sum-of-cylinders method.
Invest Radiol. 1994 May;29(5):536-9. doi: 10.1097/00004424-199405000-00002.

引用本文的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验