Vidarsson Logi, Gold Garry E, Hargreaves Brian, Pauly John M
Magnetic Resonance Systems Research Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California 94305-9510, USA.
Magn Reson Med. 2006 May;55(5):1191-6. doi: 10.1002/mrm.20878.
Recently a novel T2 selective imaging method based on linear combination (LC) filtering was developed. By linearly combining images acquired with different echo times LC filtering is able to generate images showing only tissues with a preselected range of T2 relaxation times. In this study the use of LC filtering in knee imaging was investigated. Three LC filters were designed: a short LC filter for imaging the knee meniscus, a medium LC filter for articular cartilage, and a long LC filter for synovial fluid. To verify the filter designs, eight phantoms with different T2 relaxation times were imaged. In addition, in vivo images were acquired from four asymptomatic volunteers and a subject with cartilage damage. T2 maps were also generated using the same source images. Signal-to-noise ratio (SNR) measurements were made of the meniscus, cartilage, and fluid regions on the three LC filtered images. The highest SNR was seen in the target tissue on each of the LC filtered images. LC filtering is a new method that can selectively image knee tissues based on their T2.
最近,一种基于线性组合(LC)滤波的新型T2选择性成像方法被开发出来。通过将不同回波时间采集的图像进行线性组合,LC滤波能够生成仅显示具有预选T2弛豫时间范围组织的图像。在本研究中,对LC滤波在膝关节成像中的应用进行了研究。设计了三种LC滤波器:一种用于膝关节半月板成像的短LC滤波器,一种用于关节软骨的中LC滤波器,以及一种用于滑液的长LC滤波器。为了验证滤波器设计,对八个具有不同T2弛豫时间的体模进行了成像。此外,从四名无症状志愿者和一名软骨损伤受试者获取了体内图像。还使用相同的源图像生成了T2图。对三张LC滤波图像上的半月板、软骨和液体区域进行了信噪比(SNR)测量。在每张LC滤波图像上的目标组织中都观察到了最高的SNR。LC滤波是一种可以基于T2对膝关节组织进行选择性成像的新方法。