J Am Soc Mass Spectrom. 2006 Jun;17(6):815-822. doi: 10.1016/j.jasms.2006.02.019. Epub 2006 Apr 17.

Abstract

Mass Spectrometry (MS) has been widely reported for measuring the conversion of substrates to products for enzyme assays. These measurements are typically performed by time-consuming LC-MS to eliminate buffer salts that interfere with electrospray ionization MS. However, matrix-assisted laser desorption ionization, time-of-flight MS (MALDI-TOF MS) offers a label-free and direct readout of substrate and product, a fast sampling rate, and is tolerant of many buffer salts, reagents, and compounds that are typically found in enzyme reaction mixtures. In this report, a demonstration of how MALDI-TOF MS can be used to directly measure ratios of substrates and products to produce IC(50) curves for rapid enzyme assays and compound screening is provided. Typical reproducibility parameters were <7% RSD-a value comparable to ESI MS quantitative assays and well within the acceptable limits for screening assays. The speed of the MALDI readout is currently about 10 s per sample, thus allowing for over 7500 samples/day. From a simplicity standpoint, the enzymatic reaction mixtures are prepared by liquid handling robots, the reactions are stopped by addition of a 10 times volume of acidic matrix solution, and the samples are simultaneously transferred to MALDI target plate for analysis. Importantly, the ratios of substrate to product are of sufficient reproducibility to eliminate the need for internal standards and, thus, minimize the cost and increasing the speed of assay development.

摘要

质谱分析法(MS)已被广泛报道用于测量酶分析中底物向产物的转化。这些测量通常通过耗时的液相色谱 - 质谱联用(LC - MS)来进行,以去除干扰电喷雾电离质谱的缓冲盐。然而,基质辅助激光解吸电离飞行时间质谱(MALDI - TOF MS)提供了对底物和产物的无标记直接读数、快速采样率,并且能够耐受酶反应混合物中常见的许多缓冲盐、试剂和化合物。在本报告中,展示了如何使用MALDI - TOF MS直接测量底物和产物的比例,以生成用于快速酶分析和化合物筛选的IC(50)曲线。典型的重现性参数为相对标准偏差(RSD)<7%——该值与电喷雾电离质谱定量分析相当,且完全在筛选分析的可接受范围内。MALDI读数的速度目前约为每个样品10秒,因此每天可处理超过7500个样品。从简便性角度来看,酶反应混合物由液体处理机器人制备,通过加入10倍体积的酸性基质溶液终止反应,然后将样品同时转移至MALDI靶板进行分析。重要的是,底物与产物的比例具有足够的重现性,无需内标,从而降低了成本并提高了分析开发的速度。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验