Suppr超能文献

飞秒激光穿透性角膜移植术的礼帽式伤口构型:一种实验室模型

Top hat wound configuration for penetrating keratoplasty using the femtosecond laser: a laboratory model.

作者信息

Ignacio Teresa S, Nguyen Thao B, Chuck Roy S, Kurtz Ronald M, Sarayba Melvin A

机构信息

Department of Ophthalmology, University of California, Irvine, CA 92697, USA.

出版信息

Cornea. 2006 Apr;25(3):336-40. doi: 10.1097/01.ico.0000179739.31196.e8.

Abstract

PURPOSE

To evaluate the mechanical stability and induced astigmatism of a modified multiplanar "top hat" wound configuration for full-thickness penetrating keratoplasty (PK) using the femtosecond laser as compared with PK in a laboratory model.

METHODS

Eight human corneoscleral rims were mounted on an artificial anterior chamber. Four samples were assigned to the traditional PK group. Four samples underwent full-thickness keratoplasty with the femtosecond laser: a 9.0-mm cylindrical cut was made from the anterior chamber into the stroma, followed by a ring-shaped (outer diameter 9.0 mm, inner diameter 7.0 mm) horizontal lamellar resection at two-thirds corneal depth and a 7.0-mm cylindrical cut from the lamellae to the corneal surface. Mechanical stability was evaluated after placement of the cardinal sutures and the running sutures.

RESULTS

In the "top hat" PK group, wound leakage occurred at 19 +/- 3.36 mm Hg after placement of the cardinal sutures and at 86.25 +/- 9.74 mm Hg after placement of the running sutures. In the traditional PK group, leakage occurred at 0 +/- 0 mm Hg and 76.25 +/- 20.98 mm Hg after placement of the cardinal sutures and running sutures, respectively. Both techniques induced steepening of the corneal curvature postop. The modified wound group showed a mean change in average K of 3.43 +/- 3.62 D, whereas the traditional PK group showed a mean change in average K of 3.21 +/- 6.67 D.

CONCLUSION

The femtosecond laser-produced "top hat" wound configuration for PK was found to be more mechanically stable than that produced by the traditional method.

摘要

目的

在实验室模型中,评估与传统穿透性角膜移植术(PK)相比,使用飞秒激光的改良多平面“礼帽式”伤口构型用于全层穿透性角膜移植术的机械稳定性和诱导散光情况。

方法

将8个人类角膜缘安装在人工前房上。4个样本被分配到传统PK组。4个样本接受飞秒激光全层角膜移植术:从前房到基质层制作一个9.0毫米的圆柱形切口,然后在角膜深度的三分之二处进行环形(外径9.0毫米,内径7.0毫米)水平板层切除,再从板层到角膜表面制作一个7.0毫米的圆柱形切口。在放置主要缝线和连续缝线后评估机械稳定性。

结果

在“礼帽式”PK组中,放置主要缝线后伤口渗漏发生时的眼压为19±3.36毫米汞柱,放置连续缝线后为86.25±9.74毫米汞柱。在传统PK组中,放置主要缝线和连续缝线后伤口渗漏发生时的眼压分别为0±0毫米汞柱和76.25±20.98毫米汞柱。两种技术术后均导致角膜曲率变陡。改良伤口组平均角膜曲率计读数(K值)的平均变化为3.43±3.62 D,而传统PK组平均K值的平均变化为3.21±6.67 D。

结论

发现飞秒激光产生的用于PK的“礼帽式”伤口构型在机械稳定性上比传统方法产生的更好。