INTRODUCTION

To evaluate the potential and feasibility of the potassium titanyl phosphate (KTP) Greenlight laser to perform partial nephrectomy in a porcine model.

TECHNICAL CONSIDERATIONS

A total of 15 laparoscopic partial nephrectomies were performed in 4 Danish land-raised pigs under anesthesia. Transperitoneal access was obtained, and using a total of four ports, the 80-W KTP laser was used to perform bilateral upper and lower pole partial nephrectomy. The procedures were done successfully without renal cooling or clamping of the vessels. The estimated blood loss for each procedure was less than 30 mL. Only in one operation, in which a secondary renal vein was transected, was any additional hemostasis required (a single Endoclip). The mean operating time was 42 minutes (range 31 to 59) for each partial nephrectomy. As demonstrated on video, smoke formation was, at times, a problem during the procedure, because it reduced visibility, making only intermittent application of laser energy possible. Histopathologic analysis of the specimens showed a zone of loss of substance (less than 1 mm) at the resection line and narrow adjacent zones on both sides of the resection line with minimal changes.

CONCLUSIONS

We have shown for the first time that normally perfused laparoscopic partial nephrectomy using the KTP laser is feasible and efficacious in the porcine model. This represents a novel application for the KTP laser, which produced excellent renal parenchymal hemostatic ablation. We are currently working on ways to improve the visibility by reducing smoke formation before undertaking a clinical trial in humans.

摘要

引言

评估磷酸钛氧钾(KTP)绿光激光在猪模型中进行部分肾切除术的潜力和可行性。

技术考量

在麻醉下对4头丹麦陆地饲养的猪进行了总共15例腹腔镜部分肾切除术。采用经腹入路,总共使用4个端口,使用80瓦KTP激光进行双侧上下极部分肾切除术。手术成功完成,无需肾脏降温或血管夹闭。每例手术估计失血量少于30毫升。仅在一例手术中,一条二级肾静脉被切断,需要额外止血(单个Endoclip)。每次部分肾切除术的平均手术时间为42分钟(范围31至59分钟)。如视频所示,手术过程中有时会出现烟雾形成的问题,因为它降低了视野,使得只能间歇性地应用激光能量。标本的组织病理学分析显示,切除线处有物质缺失区域(小于1毫米),切除线两侧相邻区域狭窄,变化极小。

结论

我们首次证明,在猪模型中使用KTP激光进行正常灌注的腹腔镜部分肾切除术是可行且有效的。这代表了KTP激光的一种新应用,它能产生出色的肾实质止血消融效果。我们目前正在研究在开展人体临床试验之前通过减少烟雾形成来改善视野的方法。