Tezel C, Urek S, Keles M, Kiral H, Koşar A, Dudu C, Arman B
Department of Thoracic Surgery, Heybeliada Chest Disease and Thoracic Surgery Training and Research Centre, Istanbul, Turkey.
Thorac Cardiovasc Surg. 2006 Apr;54(3):193-7. doi: 10.1055/s-2005-872951.
Bronchopleural fistula is a serious complication of major lung resections that may lead to mortality. An experimental animal model was designed to find out the safest bronchial closure method by comparing leakage rates under pressure.
The tracheobronchial trees of 50 freshly dead sheep were prepared for either manual closure or closure with a stapler. After left pneumonectomy, the specimens were divided into five groups (n = 10); 3/0 Premilene suture was used with two "u" sutures + interrupted sutures in Group I; in Group II, 3/0 Premilene sutures with continuous horizontal mattress + over-over continuous sutures were used. In Group III and IV the same techniques were used with 3/0 Vicryl. A stapler was used in Group V. Specimens were intubated with an endotracheal tube, connected to a sphygmomanometer, and subsequently positioned under water. The pressure level at which we detected air bubbles indicated the limits of the technique.
The median leakage pressure resistance was significantly lower in Group III (135 mm Hg) ( P = 0.001). The best results were achieved by using the continuous horizontal mattress + over-over continuous suture technique. No statistical significance difference was found between the stapler group, Groups I, II, and IV in terms of median leakage pressures.
This trial suggests that manual suture closure using an appropriate technique and monofilament materials is as safe as the stapler.
支气管胸膜瘘是肺大手术的严重并发症,可能导致死亡。设计了一种实验动物模型,通过比较压力下的漏气率来找出最安全的支气管闭合方法。
对50只新鲜死亡绵羊的气管支气管树进行处理,分别采用手工闭合或吻合器闭合。左肺切除术后,将标本分为五组(n = 10);第一组使用3/0普理灵缝线,采用两根“U”形缝线加间断缝线;第二组使用3/0普理灵缝线,采用连续水平褥式加连续锁边缝合。第三组和第四组使用相同技术,缝线为3/0薇乔。第五组使用吻合器。将标本插入气管内导管,连接至血压计,随后置于水下。检测到气泡时的压力水平表明了该技术的极限。
第三组的中位抗漏压力显著较低(135 mmHg)(P = 0.001)。采用连续水平褥式加连续锁边缝合技术取得了最佳效果。吻合器组与第一组、第二组和第四组在中位漏气压方面无统计学显著差异。
该试验表明,采用适当技术和单丝材料进行手工缝合闭合与吻合器一样安全。