Lin Ye, Wang Ying, Cui Hong-yan, Li Jian-hui, Qiu Li-xin, Wang Xing
Center of Dental Implantation, Peking University School and Hospital of Stomatology, Beijing 100081, China.
Zhonghua Kou Qiang Yi Xue Za Zhi. 2006 Feb;41(2):65-8.
To evaluate clinical results and technical characteristics of implant-retained facial prosthesis.
Six patients with facial defects underwent implant retained prosthesis treatment, of which 3 orbita defects (including upper and lower eyelids, eyeball) in 3 cases, 2 ears defects in 2 cases, and a nose defect in one case. Under local anaesthesia 21 extra-oral implant were placed, facial prosthesis were individually made six month postoperatively. Follow up ranged from 6 month to 6 years.
All 21 implants osseointegrated well, implant lost and peri implantitis was not found. All 6 cases had individual facial prosthesis and were satisfied with the prosthesis.
Extra oral implants provided excellent retainment for facial prosthesis; result of current silicon with individual color shade is encouragable.