Suppr超能文献

双层还是单层手套:小儿骨科手术中哪种更安全。

Double or single gloves: which is safer in pediatric orthopedic surgery.

作者信息

Al-Habdan Ibrahim, Corea J Ran, Sadat-Ali Mir

机构信息

College of Medicine, University Department of Orthopedic Surgery, King Fahd Hospital, King Faisal University, Al-Khobar, Saudi Arabia.

出版信息

J Pediatr Orthop. 2006 May-Jun;26(3):409-11. doi: 10.1097/01.bpo.0000217728.01170.4b.

Abstract

BACKGROUND AND AIM

Surgical gloves should form an efficient barrier between surgeons and patients to prevent cross infection. Single gloves (SGs) have long been reported unsafe, and usage of double gloves (DGs) is still not universal. No study has reported the usage of DGs in pediatric orthopedic operations. The aim of this study was to assess the efficacy of DGs versus SGs in prevention of body fluid contact between patients and surgeons during pediatric orthopedic surgery.

METHODOLOGY

After 150 pediatric orthopedic operations, DGs and SGs were collected and tested for perforations. Gloves were tested for size, site, and number of perforations among principal surgeons, assistant surgeons, and scrub nurses. Gloves were not changed during long surgical procedures and were changed only if perforations were identified and recorded. The DGs used were Maxitex Duplex, powder-free indicator gloves and the SGs were of Gammex-Ansell. One hundred unused gloves of each group were tested as controls. Medical records of the patients were reviewed for age, sex, type of operation, duration of operation, and any postoperative wound infection. The data were entered in database and analyzed using SPSS package. The data were compared between double and SGs using t test with a level of statistical significance at P less than 0.05.

RESULTS

Five hundred twenty-six DGs and 316 SGs were tested. Forty-three perforations were detected in DGs (8.1%). Outer gloves were breached in 7.8% and inner in 0.3% as compared with SGs in which 28 (8.7%) were perforated. In DGs, 4% had multiple perforations compared with 11.9% in SGs. There was a statistical significance (P<0.001) when the perforations of inner gloves were compared with the SGs. None of the inner perforations were recognized during surgery, but the outer gloves of the DGs were recognized in 71% as compared with 9% in SGs (P<0.001). The majority of perforations were seen in the nondominant hand in surgeons and assistants hands, whereas scrub nurses had 85% of perforations in the dominant hand. The index finger was the site of perforations in DGs (53.4%; SGs, 43%). The inner gloves were breached only when the outer glove was found to be perforated. The duration of surgery had a direct impact on the number of perforations. There were no perforations in DGs in less than 60 minutes as compared with 3 (10.7%) in SGs. Between 60 and 120 minutes, the perforations in the DGs were 11, and in SGs, 21. During the study period, 4 patients had surgical site infection. Three were superficial and one deep-seated infection. In 3 patients with infection, the gloves were found to be perforated, and 1 patient with infection had no perforations in the gloves.

CONCLUSION

Our study confirms that DGs are safer than SGs during pediatric orthopedic operations. In the event of nonavailability of DGs, SGs should be changed on an hourly basis during long procedures. Lastly, there exists a relationship between surgical site infection and glove perforations.

摘要

背景与目的

手术手套应在外科医生和患者之间形成有效的屏障,以防止交叉感染。长期以来,单手套(SGs)被报道不安全,而双层手套(DGs)的使用仍未普及。尚无研究报道双层手套在小儿骨科手术中的使用情况。本研究的目的是评估双层手套与单手套在小儿骨科手术中预防患者与外科医生之间体液接触的效果。

方法

在150例小儿骨科手术后,收集双层手套和单手套并检测是否有穿孔。对主刀医生、助手和洗手护士的手套进行尺寸、穿孔部位和穿孔数量的检测。在长时间的手术过程中手套不更换,只有在发现并记录有穿孔时才更换。所使用的双层手套为Maxitex Duplex无粉指示手套,单手套为Gammex - Ansell手套。每组100只未使用的手套作为对照进行检测。查阅患者的病历,了解患者的年龄、性别、手术类型、手术时间以及任何术后伤口感染情况。将数据录入数据库并使用SPSS软件包进行分析。使用t检验比较双层手套和单手套的数据,统计学显著性水平为P<0.05。

结果

共检测了526只双层手套和316只单手套。双层手套中检测到43处穿孔(8.1%)。外层手套穿孔率为7.8%,内层手套穿孔率为0.3%;相比之下,单手套中有28只(8.7%)穿孔。双层手套中有4%有多处穿孔,而单手套中为11.9%。内层手套的穿孔情况与单手套相比具有统计学显著性(P<0.001)。手术过程中未发现内层手套有穿孔,但双层手套的外层手套有71%被发现穿孔,而单手套为9%(P<0.001)。大多数穿孔出现在外科医生和助手的非优势手上,而洗手护士85%的穿孔出现在优势手上。双层手套中穿孔部位以食指最多(53.4%;单手套为43%)。只有当外层手套被发现穿孔时,内层手套才会破损。手术时间对穿孔数量有直接影响。手术时间少于60分钟时,双层手套无穿孔,而单手套有3只(10.7%)穿孔。手术时间在60至120分钟之间时,双层手套穿孔11处,单手套穿孔21处。在研究期间,4例患者发生手术部位感染。3例为浅表感染,1例为深部感染。在3例感染患者中,发现手套有穿孔,1例感染患者手套无穿孔。

结论

我们的研究证实,在小儿骨科手术中双层手套比单手套更安全。如果没有双层手套,在长时间手术过程中,单手套应每小时更换一次。最后,手术部位感染与手套穿孔之间存在关联。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验