A series of nasopharyngeal appliance designs is presented that represents our evolving experience over a 20-year period in the adjunctive use of prosthetic stents in the surgical correction of nasopharyngeal stenosis.
Retrospective assessment of effectiveness of two nasopharyngeal stenosis hollow stent designs in a consecutive series of patients for relief of nasal obstructive symptoms.
Tertiary academic medical center, Craniofacial Program at Children's Hospital.
Four patients with nasopharyngeal stenosis were treated with a preoperatively fabricated stent made from a clasped palatal appliance onto which hollow acrylic conduits were extended through surgically re-created pharyngeal ports. A subsequent set of four patients with nasopharyngeal stenosis were treated with intraoperatively-fashioned silastic grommets, as opposed to palatal appliances.
Postoperative intraoral stenting of nasopharyngeal ports.
Maintenance of pharyngeal port opening after 1 year, improvement in nasal airway obstructive symptoms.
The palatal appliance stents were less well tolerated and had a lower maintenance of port patency after device removal (4 of 8, 50%). The silastic grommets provided better retention into the ports and increased patient tolerance, as well as better 1-year port maintenance (6 of 8, 75%).
The grommet stent appliance offers numerous advantages over a conventional dental-clasped appliance for prosthetic nasopharyngeal stenting, including obviation of extensive preoperative preparation, ease of insertion and removal, and exchange of air during the stenting period. Improved nasopharyngeal patency with this device may be due to greater patient tolerance and subsequent longer use.
介绍一系列鼻咽部矫治器设计,这些设计代表了我们在20年期间在鼻咽狭窄手术矫正中辅助使用假体支架的不断演变的经验。
对连续系列患者中两种鼻咽狭窄空心支架设计缓解鼻阻塞症状的有效性进行回顾性评估。
三级学术医疗中心,儿童医院颅面项目。
4例鼻咽狭窄患者接受了术前制作的支架治疗,该支架由带扣腭矫治器制成,空心丙烯酸导管通过手术重新创建的咽口延伸。随后的4例鼻咽狭窄患者接受了术中制作的硅橡胶索环治疗,而不是腭矫治器。
鼻咽口术后口腔内支架置入。
1年后咽口开放的维持情况,鼻气道阻塞症状的改善情况。
腭矫治器支架的耐受性较差,取出装置后端口通畅的维持率较低(8例中的4例,50%)。硅橡胶索环在端口中的固定性更好,提高了患者的耐受性,1年端口维持情况也更好(8例中的6例,75%)。
对于鼻咽部假体支架置入,索环支架矫治器比传统的带扣牙齿矫治器具有许多优势,包括无需广泛的术前准备、易于插入和取出以及在支架置入期间的空气交换。使用该装置改善鼻咽通畅可能是由于患者耐受性提高以及随后使用时间延长。