Pohl Marcus, Mehrholz Jan
Department of Early Neurological Rehabilitation, Klinik Bavaria, Kreischa, Germany.
Clin Rehabil. 2006 Apr;20(4):324-30. doi: 10.1191/0269215506cr951oa.
To evaluate the immediate effects of individually designed functional in-shoe ankle-foot orthoses (AFO) made of soft and hard cast on balance, standing, and gait parameters in hemiparetic patients.
Crossover design with randomized order of the intervention.
A rehabilitation centre for adults with neurological disorders.
Twenty-eight patients with hemiparesis due to stroke or traumatic brain injury.
Postural sway, standing and gait parameters based on ground reaction forces in two conditions: Patients were randomly assigned to varying sequences of wearing AFO in footwear or wearing footwear alone.
AFO significantly improved weight-bearing on the affected leg (affected/ unaffected side symmetry: 2.25 +/- 1.5 with AFO versus 3.4 +/- 2.5 without AFO, P<0.05) and postural sway in stance (12.5 mm +/- 5.2 with AFO versus 15.7 mm +/- 6.7 without AFO, P < 0.05), double stance duration (21.1 +/-14.4% of gait cycle with AFO versus 25.9 +/- 21.6% of gait cycle without AFO, P < 0.05), and symmetry ratios of gait parameters such as stance duration (2.0 +/- 1.5 s with AFO versus 3.3 +/- 3.6 s without AFO, P < 0.05) and deceleration forces (1.6 +/- 0.5 with AFO versus 1.9 +/- 0.6 without AFO, P < 0.05) during gait. No significant differences were observed in all other symmetry ratios of gait parameters.
An individually designed functional in-shoe AFO can improve stance and gait parameters, even in a single use, in patients with hemiparesis.
评估由软硬石膏制成的个性化功能性鞋内踝足矫形器(AFO)对偏瘫患者平衡、站立和步态参数的即时影响。
采用交叉设计,干预顺序随机。
一家成人神经疾病康复中心。
28例因中风或创伤性脑损伤导致偏瘫的患者。
基于地面反作用力的姿势摆动、站立和步态参数,分为两种情况:患者被随机分配到不同的穿戴顺序,即穿带有AFO的鞋子或只穿鞋子。
AFO显著改善了患侧腿的负重(患侧/健侧对称率:使用AFO时为2.25±1.5,不使用AFO时为3.4±2.5,P<0.05)以及站立时的姿势摆动(使用AFO时为12.5mm±5.2,不使用AFO时为15.7mm±6.7,P<0.05)、双支撑期(使用AFO时占步态周期的21.1±14.4%,不使用AFO时占步态周期的25.9±21.6%,P<0.05),以及步态参数的对称率,如步态支撑期(使用AFO时为2.0±1.5秒,不使用AFO时为3.3±3.6秒,P<0.05)和减速力(使用AFO时为1.6±0.5,不使用AFO时为1.9±0.6,P<0.05)。在所有其他步态参数的对称率方面未观察到显著差异。
个性化设计的功能性鞋内AFO即使在单次使用时也能改善偏瘫患者的站立和步态参数。