Suppr超能文献

不同脉动冲洗压力对松质骨结构和骨折愈合的影响。

Effects of varying pulsatile lavage pressure on cancellous bone structure and fracture healing.

作者信息

Polzin Britton, Ellis Thomas, Dirschl Douglas R

机构信息

Department of Orthopaedics and Rehabilitation, Oregon Health and Science University, Portland, Oregon, USA.

出版信息

J Orthop Trauma. 2006 Apr;20(4):261-6. doi: 10.1097/00005131-200604000-00005.

Abstract

OBJECTIVE

To study the effects of variations in pulsatile lavage irrigation pressure on the rate of new bone formation and the degree to which cellular elements are removed from cancellous bone after fracture.

DESIGN

A previously described intraarticular fracture model was used for 29 New Zealand white rabbits that underwent osteotomy of the medial femoral condyle. Fractures were irrigated with high-pressure pulsatile lavage at a fixed distance and volume, but at nozzle pressures varying from 20 to 70 psi. Fractures were reduced and stabilized, and animals euthanized 14 days after fracture. Fluorescent bone staining was used to determine the rate of new bone formation in the osteotomy site. At the time of euthanasia, the nonoperated knees of 12 rabbits underwent osteotomy and irrigation using the same protocol. These specimens were sent for immediate scanning electron microscopy to determine the amount of cellular material removed from the bony trabeculae.

RESULTS

In the first week after irrigation, there was no significant difference in the amount of new bone formation between the 20- and 30-psi groups, but there were significant differences between these groups and the 50- and 70-psi groups. There were no significant differences between any of the groups in the amount of new bone formed during the second week after irrigation. No structural damage to the bony trabeculae was observed in any specimen irrigated at any of the pressures used. There was a direct correlation between percentage of the trabecula completely cleared of cellular material and irrigation pressure; there were statistically significant differences between each of the groups.

CONCLUSIONS

There are presently no recommended guidelines as to the optimal irrigation pressure, and this study is the first to address the effects of variations in pressure on bone healing. The results of this study indicate that early new bone formation in an intraarticular fracture rabbit model is inhibited by irrigation pressure of 50 psi or greater. Additionally, this study demonstrates a direct relationship between irrigation pressure and the amount of cellular material removed from the trabecula at the irrigation site. Surgeons should be aware of the potentially detrimental effects of using irrigation pressures at or above 50 psi in the treatment of fractures.

摘要

目的

研究脉冲冲洗压力变化对骨折后松质骨新骨形成速率以及细胞成分清除程度的影响。

设计

采用先前描述的关节内骨折模型,对29只接受股骨内侧髁截骨术的新西兰白兔进行实验。骨折部位以固定距离和体积进行高压脉冲冲洗,但喷嘴压力在20至70磅力/平方英寸之间变化。骨折复位并固定,动物在骨折后14天安乐死。使用荧光骨染色法测定截骨部位的新骨形成速率。在安乐死时,12只兔子的未手术膝关节按照相同方案进行截骨和冲洗。这些标本立即送去进行扫描电子显微镜检查,以确定从骨小梁中清除的细胞物质数量。

结果

冲洗后第一周,20磅力/平方英寸和30磅力/平方英寸组之间的新骨形成量无显著差异,但这两组与50磅力/平方英寸和70磅力/平方英寸组之间存在显著差异。冲洗后第二周,各实验组之间新骨形成量无显著差异。在任何所使用压力下冲洗的任何标本中均未观察到骨小梁的结构损伤。骨小梁细胞物质完全清除百分比与冲洗压力之间存在直接相关性;各实验组之间存在统计学显著差异。

结论

目前尚无关于最佳冲洗压力的推荐指南,本研究首次探讨了压力变化对骨愈合的影响。本研究结果表明,在关节内骨折兔模型中,50磅力/平方英寸或更高的冲洗压力会抑制早期新骨形成。此外,本研究表明冲洗压力与冲洗部位骨小梁中清除的细胞物质数量之间存在直接关系。外科医生应意识到在骨折治疗中使用50磅力/平方英寸及以上冲洗压力可能产生的有害影响。