Determining 234Th and 238U in rocks, soils, and sediments via the doublet gamma at 92.5 keV.

作者信息

Kaste James M, Bostick Benjamin C, Heimsath Arjun M

机构信息

Department of Earth Sciences, Dartmouth College, Hanover, NH 03755, USA.

出版信息

Analyst. 2006 Jun;131(6):757-63. doi: 10.1039/b600202a. Epub 2006 May 15.

Abstract

Efficient and accurate measurements of uranium (U) and U-series radionuclides in earth's materials are needed to assess its environmental impact, reconstruct geochemical histories, and quantify heat production in the crust. To date, measurements of 234Th and 238U by gamma spectrometry have relied on the quantification of 234Th gamma emissions at approximately 63 keV (absolute intensity = 3.7%) and the (234m)Pa gamma at 1001 keV (absolute intensity = 0.84%). However, use of the 63 keV emissions can be hampered by 232Th interferences and self absorption, and the 1001 keV photon has a very low yield. Here we describe the effective use of the 234Th doublet gamma emission at approximately 92.5 keV (total absolute intensity = 4.8%) for 234Th and 238U measurements. This doublet has been largely ignored because of its proximity to the Th K(alpha1) (93.3 keV) and thus its vulnerability to a Th self-fluorescence interference. We demonstrate that additions of U and 40K to a Th ore sample do not increase the count rate at 92-93 keV above that which would be expected from the associated additions of U and 234Th. We also show that the Th self-fluorescence interference appears to be an anomaly associated only with the analysis of relatively thick (>1 mm) Th minerals, and suggest that fluorescence will not complicate the 92-93 keV region in most environmental samples. A review of decay data reveals that Th K(alpha1) X-rays associated with the decay of 235U and 228Ac can significantly interfere with quantification of the 92.5 keV 234Th doublet. We show that simple experimentally-derived correction factors for these X-rays can be used to accurately determine 234Th using its strongest gammas, resulting in higher count rates and smaller self-absorption corrections relative to the traditional analytical lines. Total 1 sigma analytical error associated with U measurements at 92.5 keV ranged from 1 to 9% and is dominated by the relative size of the 228Ac interference. Detection limits for U in environmental samples using this technique are on the order of 50 ppb.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验