Impurities in a lyophilized formulation of BMS-204352: identification and role of sanitizing agents.

作者信息

Nassar Munir N, Nesarikar Vishwas V, Khaselev Nona, Lozano Ruben

机构信息

Biopharmaceutics Research and Development, Pharmaceutical Research Institute, Bristol-Myers Squibb, New Brunswick, NJ 08903, USA.

出版信息

Pharm Dev Technol. 2006;11(2):207-11. doi: 10.1080/10837450600561323.

DOI:10.1080/10837450600561323
PMID:16749531
Abstract

The purpose of this study was to identify two impurities in the parenteral lyophilized formulation of BMS-204352, investigate the role of sanitizing agents as their potential source, evaluate their effect on drug product stability, and develop a strategy to prevent their contamination of the drug product. The two impurities were identified as o-phenylphenol and 4-t-amylphenol based on liquid chromatography/mass spectroscopy (LC/MS) and chromatographic comparison to authentic samples. The LC/MS spectra of commercially available o-phenylphenol and 4-t-amylphenol showed identical patterns of fragmentation and the same retention times as the impurities identified in the BMS-204352 lyophilized product. Levels of these impurities were low and ranged between 0.2-0.3 microg/vial as determined by HPLC and using an authentic external reference standard. To confirm the hypothesis that the commercial sanitizing agents used in the sterile area were the source of these phenolic impurities, several product samples were spiked with the sanitizing agents. Both o-phenylphenol and 4-t-amylphenol were detected in the spiked samples. Further investigation revealed that o-phenylphenol and 4-t-amylphenol are active ingredients of these commercial sanitizing agents. Drug product samples containing the phenolic impurities showed no potency loss following storage at 30, 50, and 70 degrees C indicating these impurities had no adverse effect on product stability. These studies suggest that sanitizing agents used in the sterile area, although may be present at trace levels below typical cleaning procedure detection methods, need to be properly controlled and closely monitored during the manufacturing of injectable products, particularly highly potent drugs. Sanitizing agents, even though not used on product contact surfaces, may potentially contaminate a product through vapor transfer in an open environment.

摘要

相似文献

1
Impurities in a lyophilized formulation of BMS-204352: identification and role of sanitizing agents.
Pharm Dev Technol. 2006;11(2):207-11. doi: 10.1080/10837450600561323.
2
Degradation of a lyophilized formulation of BMS-204352: identification of degradants and role of elastomeric closures.BMS-204352冻干制剂的降解:降解产物的鉴定及弹性密封件的作用
Pharm Dev Technol. 2005;10(2):227-32. doi: 10.1081/pdt-54429.
3
Cleaning validation 1: development and validation of a chromatographic method for the detection of traces of LpHse detergent.
J Pharm Biomed Anal. 2006 May 3;41(2):589-93. doi: 10.1016/j.jpba.2005.10.049. Epub 2006 Jan 10.
4
Oxidation of protein by vaporized sanitizing agents.蛋白质被汽化消毒剂氧化。
PDA J Pharm Sci Technol. 2004 May-Jun;58(3):121-9.
5
Single-laboratory validation of a method for the determination of phenols and phenates in disinfectant formulations by liquid chromatography with UV detection.
J AOAC Int. 2010 May-Jun;93(3):1039-45.
6
Influence of formaldehyde impurity in polysorbate 80 and PEG-300 on the stability of a parenteral formulation of BMS-204352: identification and control of the degradation product.聚山梨酯80和聚乙二醇-300中甲醛杂质对BMS-204352注射剂稳定性的影响:降解产物的鉴定与控制
Pharm Dev Technol. 2004;9(2):189-95. doi: 10.1081/pdt-120030249.
7
Determination of phenolic disinfectant agents in commercial formulations by liquid chromatography.
J AOAC Int. 2001 May-Jun;84(3):815-22.
8
Highly efficient, selective, sensitive and stability indicating RP-HPLC-UV method for the quantitative determination of potential impurities and characterization of four novel impurities in eslicarbazepine acetate active pharmaceutical ingredient by LC/ESI-IT/MS/MS.一种高效、选择性、灵敏且稳定的反相高效液相色谱-紫外检测法,用于定量测定依佐加滨醋酸盐原料药中潜在杂质和 4 种新杂质的特征,采用 LC/ESI-IT/MS/MS。
J Pharm Biomed Anal. 2012 Mar 5;61:165-75. doi: 10.1016/j.jpba.2011.11.024. Epub 2011 Dec 1.
9
[Identification of the impurities in -chlorophenyl cyclopentyl ketone samples by high performance liquid chromatography-hybrid ion trap/time-of-flight mass spectrometry and preparation of -chlorophenyl cyclopentyl ketone standard].[采用高效液相色谱-混合离子阱/飞行时间质谱法鉴定氯代苯基环戊基酮样品中的杂质并制备氯代苯基环戊基酮标准品]
Se Pu. 2018 Mar 8;36(3):268-277. doi: 10.3724/SP.J.1123.2017.11034.
10
Pharmaceutical development of a parenteral lyophilized formulation of the novel indoloquinone antitumor agent EO9.新型吲哚醌抗肿瘤药物EO9的肠胃外冻干制剂的药物研发
Cancer Chemother Pharmacol. 1994;34(5):416-22. doi: 10.1007/BF00685567.