Suppr超能文献

基于检测理论模型的影响腰骶神经根病变F波潜伏期检测的因素

Factors influencing F-wave latency detection of lumbosacral root lesions using a detection theory based model.

作者信息

Gozani Shai N, Kong Xuan, Fisher Morris A

机构信息

NeuroMetrix, Inc., 62 Fourth Avenue, Waltham, MA 02451, USA.

出版信息

Clin Neurophysiol. 2006 Jul;117(7):1449-57. doi: 10.1016/j.clinph.2006.04.001. Epub 2006 Jun 8.

Abstract

OBJECTIVE

To evaluate the F-wave dilution hypothesis; which implies that absolute F-wave latencies obscure the much smaller delay associated with slow intra-lesion conduction, such is caused by nerve root compression in lumbosacral radiculopathy. A corollary objective is to determine how F-wave measurement and pathological factors influence diagnostic accuracy.

METHODS

An analytical model is developed based on signal detection theory and a number of simplifying assumptions. Diagnostic accuracy, quantified by the area under the receiver operating characteristic (ROC) curve, is determined for various model realizations derived from the clinical and experimental neurophysiology literature. A preliminary experimental validation of model predictions is also performed.

RESULTS

Absolute F-wave latency does not influence the accuracy of focal lesion detection. F-wave latency variance and lesion pathology are the determinant factors. F-wave latencies and distal latencies are estimated to have qualitatively similar detection characteristics, although distal latencies have quantitatively better diagnostic efficacy for comparable focal pathology. Preliminary experimental results support the modeled dependence of diagnostic accuracy on latency variance and lesion severity.

CONCLUSIONS

Absolute F-wave latency does not dilute slow conduction within focal lesions, such as in lumbosacral radiculopathy. The dominant measurement factor is F-wave latency variance.

SIGNIFICANCE

To maximize the diagnostic utility of F-wave latencies, focus must be placed on reducing latency variance, such as through correction for demographic covariates. This model calls into question the F-wave dilution hypothesis.

摘要

目的

评估F波稀释假说;该假说认为,绝对F波潜伏期掩盖了与病变内缓慢传导相关的小得多的延迟,这种延迟是由腰骶神经根病中的神经根受压引起的。一个必然目标是确定F波测量和病理因素如何影响诊断准确性。

方法

基于信号检测理论和一些简化假设开发了一个分析模型。通过接收者操作特征(ROC)曲线下面积量化的诊断准确性,针对从临床和实验神经生理学文献中得出的各种模型实现进行确定。还对模型预测进行了初步实验验证。

结果

绝对F波潜伏期不影响局灶性病变检测的准确性。F波潜伏期方差和病变病理是决定因素。估计F波潜伏期和远端潜伏期具有定性相似的检测特征,尽管对于相当的局灶性病变,远端潜伏期在定量上具有更好的诊断效能。初步实验结果支持了诊断准确性对潜伏期方差和病变严重程度的模型依赖性。

结论

绝对F波潜伏期不会稀释局灶性病变(如腰骶神经根病)内的缓慢传导。主要的测量因素是F波潜伏期方差。

意义

为了最大限度地提高F波潜伏期的诊断效用,必须注重减少潜伏期方差,例如通过校正人口统计学协变量。该模型对F波稀释假说提出了质疑。