Zhang Deng-jun, Chen Jian-ting, Jin Da-di
Department of Spinal and Orthopedic Surgery, Nanfang Hospital, Southern Medical University, Guangzhou 510515, China.
Nan Fang Yi Ke Da Xue Xue Bao. 2006 May;26(5):705-6, 710.
To test the efficacy of kyphoplasty using an enhanced balloon expander in restoring the height of vertebral compression fractures (OVCF).
Fifteen lumbar vertebral bodies (L1-L5) were harvested from 3 young male fresh cadavers and separated into individual vertebral bodies with the bilateral pedicles of the vertebral arch removed. Before operation, plain X-ray films of all the vertebral bodies were obtained. All the vertebral bodies were compressed lengthwise to approximately 80% of their original heights using a universal material-testing machine to result in compression fractures. Post-compression vertebral bodies were then repaired using an enhanced balloon expander, and the delivery of the bone cement into the vertebral bodies was observed. The heights of the anterior and posterior borders of the vertebral bodied were measured before and after compression as well as after kyphoplasty.
The inflation of the balloon expander averaged 2.95-/+0.18 ml and the pressure was 122.67-/+27.89 psi (1 psi=6895 Pa). Kyphoplasty resulted in significant restoration of the vertebral body height lost due to the compression (P<0.01).
Kyphoplasty using an enhanced balloon expander may restore vertebral body height damaged by compression and correct the kyphotic deformity. The balloon expander can be a effective and economic choice for kyphoplasty for its relatively low cost.
测试使用增强型球囊扩张器进行椎体后凸成形术恢复椎体压缩性骨折(OVCF)高度的疗效。
从3具年轻男性新鲜尸体上获取15个腰椎椎体(L1-L5),并分离成单个椎体,去除双侧椎弓根。术前,获取所有椎体的X线平片。使用万能材料试验机将所有椎体纵向压缩至其原始高度的约80%,导致压缩性骨折。然后使用增强型球囊扩张器修复压缩后的椎体,并观察骨水泥注入椎体的情况。测量椎体压缩前后以及椎体后凸成形术后椎体前后缘的高度。
球囊扩张器的平均膨胀量为2.95±0.18 ml,压力为122.67±27.89 psi(1 psi = 6895 Pa)。椎体后凸成形术使因压缩而丢失的椎体高度得到显著恢复(P<0.01)。
使用增强型球囊扩张器进行椎体后凸成形术可恢复因压缩而受损的椎体高度并纠正后凸畸形。由于成本相对较低,球囊扩张器对于椎体后凸成形术而言可能是一种有效且经济的选择。