Suppr超能文献

次氯酸盐溶液反复浸泡后石膏模型的表面细节、抗压强度和尺寸精度。

Surface detail, compressive strength, and dimensional accuracy of gypsum casts after repeated immersion in hypochlorite solution.

作者信息

Abdullah Mohammed Aleem

机构信息

Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Kingdom of Saudi Arabia.

出版信息

J Prosthet Dent. 2006 Jun;95(6):462-8. doi: 10.1016/j.prosdent.2006.03.019.

Abstract

STATEMENT OF PROBLEM

One method used to disinfect a dental cast is immersion in a disinfecting solution. Repeated immersion of a cast in disinfectant may affect surface detail as well as other physical properties.

PURPOSE

The purpose of this study was to evaluate the changes in surface detail quality, dimensional accuracy, and wet compressive strength of dental casts as a result of repeated disinfection in slurry containing 0.525% sodium hypochlorite solution.

MATERIAL AND METHODS

Two different test specimen configurations were used, one for evaluating surface detail quality and dimensional accuracy and the other for compressive strength. Sixty specimens each were made of type III and type IV dental stone (Excalibur). Thirty specimens were immersed in slurry, a supernatant solution of calcium sulfate in distilled water (control casts), and 30 in slurry with sodium hypochlorite (test casts) solutions for 30 minutes and air dried for 24 hours. This process was repeated 7 times before testing. Linear dimensional change, surface detail quality, and wet compressive strength were determined according to American National Standards Institute/American Dental Association (ANSI/ADA) standards. The data were analyzed using 2-way analysis of variance and 2-sample independent t tests (alpha=.05).

RESULTS

For specimens prepared with type III and type IV stone, treatment by immersion in slurry (control casts) and in slurry with sodium hypochlorite (test casts) resulted in an increase (P<.0001) in linear dimensional change. The type IV casts treated with slurry with sodium hypochlorite showed significantly less (P<.0001) mean linear dimensional change (0.025%) compared with type III stone casts (0.063%), and the values remained within the ANSI/ADA specified standards. Both test solutions caused some degree of erosion or damage to the surface quality of casts made from type III and type IV stones. However, the difference between the control and test casts was not significant. Slurry with 0.525% sodium hypochlorite solution decreased the compressive strength of both types of stones significantly (P<.001) compared with distilled water slurry. However, the values remained close to ANSI/ADA standards.

CONCLUSION

The results demonstrated that repeated immersion of type III and type IV stone specimens in slurry with distilled water and slurry with 0.525% sodium hypochlorite, along with drying in air, caused a significant increase in linear dimension and a significant decrease in wet compressive strength. Although both the solutions caused some degree of damage to surface details for type III and type IV stones, the difference was not significant.

摘要

问题陈述

用于消毒牙模的一种方法是将其浸入消毒溶液中。牙模反复浸入消毒剂中可能会影响表面细节以及其他物理性能。

目的

本研究的目的是评估牙模在含有0.525%次氯酸钠溶液的浆液中反复消毒后表面细节质量、尺寸精度和湿抗压强度的变化。

材料与方法

使用两种不同的试样配置,一种用于评估表面细节质量和尺寸精度,另一种用于评估抗压强度。每种类型III和类型IV牙科石膏(Excalibur)各制作60个试样。30个试样浸入蒸馏水中硫酸钙的上清液(对照牙模)制成的浆液中,30个试样浸入含有次氯酸钠的浆液(测试牙模)中30分钟,然后风干24小时。在测试前,这个过程重复7次。根据美国国家标准学会/美国牙科协会(ANSI/ADA)标准测定线性尺寸变化、表面细节质量和湿抗压强度。使用双向方差分析和双样本独立t检验(α = 0.05)对数据进行分析。

结果

对于用类型III和类型IV石膏制备的试样,浸入蒸馏水中硫酸钙的上清液(对照牙模)和含有次氯酸钠的浆液(测试牙模)处理后,线性尺寸变化增加(P < 0.0001)。与类型III石膏牙模(0.063%)相比,用含有次氯酸钠的浆液处理的类型IV牙模的平均线性尺寸变化显著更小(P < 0.0001)(0.025%),且这些值仍在ANSI/ADA规定的标准范围内。两种测试溶液都对由类型III和类型IV石膏制成的牙模的表面质量造成了一定程度的侵蚀或损坏。然而,对照牙模和测试牙模之间的差异不显著。与蒸馏水浆液相比,含有0.525%次氯酸钠溶液的浆液显著降低了两种类型石膏的抗压强度(P < 0.001)。然而,这些值仍接近ANSI/ADA标准。

结论

结果表明,类型III和类型IV石膏试样反复浸入蒸馏水中硫酸钙的上清液和含有0.525%次氯酸钠的浆液中,并在空气中干燥,会导致线性尺寸显著增加,湿抗压强度显著降低。虽然两种溶液都对类型III和类型IV石膏的表面细节造成了一定程度的损坏,但差异不显著。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验