Agarwal Amar, Jacob Soosan, Agarwal Athiya, Agarwal Sunitha, Kumar M Ashok
Dr. Agarwal's Eye Hospital, Chennai, India.
J Cataract Refract Surg. 2006 May;32(5):895-7. doi: 10.1016/j.jcrs.2006.01.070.
During clear corneal temporal phacoemulsification, an accidental iatrogenic descemetorhexis occurred. The entire cornea was hazy and edematous on the first postoperative day. By the 1-month postoperative review, the cornea had become clear with visible descemetorhexis margins; best corrected visual acuity was 20/25, and the pachymetry was 556 microm. The patient remained stable at the 2-years postoperative follow-up, and specular microscopy done at this time showed a cell density of 1301 cells/mm2 with evidence of pleomorphism and polymegethism. This is the first report of iatrogenic descemetorhexis in which the cornea had become clear and nonedematous by as early as 1 month postoperatively. This case highlights that a healthy endothelium can maintain corneal deturgescence despite a low endothelial cell count. Corneal thickness increases only when the number of endothelial cells has gone below a physiologic lower limit.
在透明角膜颞侧白内障超声乳化手术过程中,意外发生了医源性后弹力层脱离。术后第一天,整个角膜模糊且水肿。术后1个月复查时,角膜已变清晰,后弹力层脱离边缘可见;最佳矫正视力为20/25,角膜厚度测量值为556微米。患者在术后2年随访时情况稳定,此时进行的角膜内皮显微镜检查显示细胞密度为1301个细胞/平方毫米,有细胞大小不均和异形性的证据。这是关于医源性后弹力层脱离的首次报告,其中角膜早在术后1个月就已变清晰且无水肿。该病例突出表明,尽管内皮细胞数量较低,但健康的内皮仍可维持角膜消肿。只有当内皮细胞数量低于生理下限后,角膜厚度才会增加。