Abstract

The treatment of positional plagiocephaly is controversial. A confounding factor is the lack of a proven clinically viable measure to quantify severity and change in plagiocephaly. The use of anthropometric measurements is one proposed method. In this study, the reliability and validity for this method of measurement were investigated. Two clinicians independently recorded caliper measurements of cranial vault asymmetry (CVA) for infants referred for plagiocephaly or torticollis, and an unbiased observer recorded visual analysis scores during the same visit. CVA scores were assigned into three predetermined severity categories (normal CVA < 3 mm, mild/moderate CVA <or= 12 mm, moderate/severe CVA > 12 mm). CVA measurements and visual analysis scores were recorded for 71 and 54 infants, respectively. Intrarater reliability was established (kappa = 0.98, kappa = 0.99), but inter-rater reliability was not (kappa = 0.42). In addition, the inter-rater reliability for the severity categories based upon these measures was poor (kappa = 0.28) and failed to correlate to the visual analysis (kappa = 0.31). Development of a stable and meaningful measurement system for the extent of plagiocephaly is needed to allow scientific studies of the natural history of plagiocephaly and effectiveness of interventions.

摘要

位置性斜头畸形的治疗存在争议。一个混杂因素是缺乏一种经证实的临床可行方法来量化斜头畸形的严重程度和变化情况。使用人体测量学方法是一种提出的方案。在本研究中,对该测量方法的可靠性和有效性进行了调查。两名临床医生独立记录因斜头畸形或斜颈前来就诊婴儿的颅骨穹窿不对称(CVA)的卡尺测量值,一名无偏见的观察者在同一次就诊期间记录视觉分析评分。CVA评分被分为三个预先确定的严重程度类别(正常CVA<3毫米,轻度/中度CVA≤12毫米,中度/重度CVA>12毫米)。分别对71名和54名婴儿记录了CVA测量值和视觉分析评分。建立了评分者内信度(kappa = 0.98,kappa = 0.99),但评分者间信度未建立(kappa = 0.42)。此外,基于这些测量的严重程度类别之间的评分者间信度较差(kappa = 0.28),且与视觉分析无相关性(kappa = 0.31)。需要开发一种用于斜头畸形程度的稳定且有意义的测量系统,以便对斜头畸形的自然史和干预效果进行科学研究。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验