Jakoniuk Piotr, Leszczyńska Katarzyna, Zalewska Marta, Sacha Paweł, Wieczorek Piotr
Zakład Diagnostyki Mikrobiologicznej Akademii Medycznej w Białymstoku.
Med Dosw Mikrobiol. 2005;57(4):431-6.
For the detection of bacteria coated with immunoglobulins in urine the monoclonal antibodies against human IgA, IgG and IgM conjugated with peroxidase were used. For comparison, the immunofluorescence technique was also employed. The results obtained by two methods revealed that immunofluorescence were less sensitive. It was found that bacteria were predominantly coated with IgA (41,9 +/- 22,4%) and IgG (34,1 +/- 15,3 %) immunoglobulins. The IgM antibodies were found rarely (12,8 +/- 8%).