Application of TL dosemeters for dose distribution measurements at high temperatures in nuclear reactors.

作者信息

Osvay M, Deme S

机构信息

Institute of Isotopes, Budapest, P.O. Box 77, H-1525, Hungary.

出版信息

Radiat Prot Dosimetry. 2006;119(1-4):271-5. doi: 10.1093/rpd/nci572. Epub 2006 Jul 4.

Abstract

Al2O3:Mg,Y ceramic thermoluminescence dosemeters were developed at the Institute of Isotopes for high dose applications at room temperatures. The glow curve of Al2O3:Mg,Y exhibits two peaks--one at 250 degrees C (I) and another peak at approximately 400 degrees C (II). In order to extend the application of these dosemeters to high temperatures, the effect of irradiation temperature was investigated using temperature controlled heating system during high dose irradiation at various temperatures (20-100 degrees C). The new calibration and measuring method has been successfully applied for dose mapping within the hermetic zone of the Paks Nuclear Power Plant even at high temperature parts of blocks.