Suppr超能文献

室间隔缺损患儿分流容积的评估:磁共振血流测量与侵入性血氧测定的比较定量分析

Assessment of shunt volumes in children with ventricular septal defects: comparative quantification of MR flow measurements and invasive oximetry.

作者信息

Esmaeili Anoosh, Höhn Rene, Koch Arne, Vogl Thomas Josef, Hofstetter Roland, Abolmaali Nasreddin

机构信息

Department of Pediatric Cardiology, Johann Wolfgang Goethe University, Hospital, Frankfurt/M, Germany.

出版信息

Clin Res Cardiol. 2006 Oct;95(10):523-30. doi: 10.1007/s00392-006-0415-6. Epub 2006 Jul 14.

Abstract

The aim of this study was to compare the results of magnetic resonance based shunt volume measurements with the results of the invasive method by the principle of Fick. In 14 children (median age: 16.5 months) with ventricular septal defects the shunt volume was quantified by magnetic resonance flow measurements under spontaneous breathing conditions as well as with invasive angiography during one sedation. A good correlation between both methods was observed (r(2) = 0.8, p <0.0001, CI(95%) = 0.62-1.22). A tendency towards higher values in the noninvasive technique was found in the Bland-Altman plot (bias = 3.79). Magnetic resonance based shunt measurements are a reliable alternative to the invasive shunt measurement by cardiac catheterization.

摘要

本研究的目的是通过菲克原理,比较基于磁共振的分流体积测量结果与侵入性方法的测量结果。在14例室间隔缺损患儿(中位年龄:16.5个月)中,在自然呼吸条件下通过磁共振血流测量以及在一次镇静期间通过侵入性血管造影对分流体积进行定量。观察到两种方法之间具有良好的相关性(r(2)=0.8,p<0.0001,CI(95%)=0.62-1.22)。在布兰德-奥特曼图中发现无创技术测量值有偏高的趋势(偏差=3.79)。基于磁共振的分流测量是心脏导管插入术侵入性分流测量的可靠替代方法。