Abstract

OBJECTIVES

To determine the ionised calcium concentration following aerobic collection of blood and to compare ionised calcium concentration and pH of heparinised whole blood and plasma at 48 hours following collection under three different storage conditions to assess if ionised calcium concentration can be measured retrospectively.

METHODS

Blood was collected from 17 dogs for analysis of ionised calcium concentration and pH using a Rapidpoint 400 (Bayer) blood gas analyser. Blood was collected into a commercial preheparinised syringe and into a plain syringe, with subsequent transfer to a commercially available heparinised sample tube. Samples were analysed within 10 minutes, and the remainder was divided for storage. One aliquot was set-aside at room temperature for 48 hours, and the other was immediately centrifuged and the plasma divided for storage at room temperature and at 4 degrees C for 48 hours each. In all samples, ionised calcium concentration and pH were measured again at 48 hours after storage.

RESULTS

There was no significant difference in ionised calcium concentration or pH between anaerobically and aerobically collected heparinised whole blood analysed within 10 minutes of collection. At 48 hours, ionised calcium concentrations had decreased under all storage conditions irrespective of the direction of pH change.

CLINICAL SIGNIFICANCE

Ionised calcium concentration can be measured in aerobically collected samples within 10 minutes and at 48 hours after collection under the conditions described.

摘要

目的

测定有氧采集血液后的离子钙浓度,并比较在三种不同储存条件下采集后48小时肝素化全血和血浆的离子钙浓度及pH值,以评估离子钙浓度是否可进行回顾性测量。

方法

从17只犬采集血液,使用Rapidpoint 400(拜耳)血气分析仪分析离子钙浓度和pH值。血液分别采集到商用预肝素化注射器和普通注射器中,随后转移至市售肝素化样本管。样本在10分钟内进行分析,其余样本进行分装储存。一份等分样本在室温下放置48小时,另一份立即离心,分离出的血浆分别在室温及4℃下各储存48小时。所有样本在储存48小时后再次测量离子钙浓度和pH值。

结果

采集后10分钟内分析的厌氧和有氧采集的肝素化全血之间,离子钙浓度或pH值无显著差异。在48小时时,无论pH值变化方向如何,所有储存条件下离子钙浓度均下降。

临床意义

在所述条件下,有氧采集的样本在采集后10分钟及48小时均可测量离子钙浓度。