Suppr超能文献

注射器类型和储存温度对马动脉血血气分析结果的影响。

Effects of syringe type and storage temperature on results of blood gas analysis in arterial blood of horses.

作者信息

Picandet Valerie, Jeanneret Stephanie, Lavoie Jean-Pierre

机构信息

Department of Clinical Sciences, Faculty of Veterinary Medicine, Université de Montréal, Saint-Hyacinthe, QC, Canada.

出版信息

J Vet Intern Med. 2007 May-Jun;21(3):476-81. doi: 10.1892/0891-6640(2007)21[476:eostas]2.0.co;2.

Abstract

BACKGROUND

Results of arterial blood gas analysis can be biased by pre-analytical factors, such as time to analysis, syringe type, and temperature during storage. However, the acceptable delay between time of collection and analysis for equine arterial blood gas remains unknown.

HYPOTHESIS

Dedicated plastic syringes provide better stability of arterial blood gases than multipurpose plastic syringes.

ANIMALS

Eight mares, 1 stallion, and 1 gelding, ages 3 to 10 years old.

METHODS

Arterial blood samples were collected in a glass syringe, a plastic syringe designated for blood gas collection, and a multipurpose tuberculin plastic syringe. Blood samples were stored at ambient temperature or in iced water. For each sample, partial pressure of oxygen in arterial blood (PaO2), partial pressure of carbon dioxide in arterial blood (PaCO2), and pH were measured within a few minutes of collection and at 5, 20, 30, 60, 90, and 120 minutes after collection.

RESULTS

Collection into glass syringes stored in iced water provided adequate PaO2 results for up to 117 +/- 35 minutes, whereas blood collected in either of the plastic syringes resulted in a variation >10 mm Hg after 10 +/- 3 to 17 +/- 2 minutes, depending on the storage conditions. Plastic syringes kept at ambient temperature offered more stability for PaCO2 analysis because they could be stored up to 83 +/- 16 minutes without significant variations. Values of pH did not show variations more than 0.02 for the first hour, irrespectively of storage condition.

CONCLUSIONS AND CLINICAL IMPORTANCE

Glass syringes placed on ice are preferable for analysis of PaO2. Blood collected in plastic syringes should be analyzed within 10 minutes, irrespective of the storage temperature, to ensure the accuracy of PaO2 values.

摘要

背景

动脉血气分析结果可能会受到分析前因素的影响,如分析时间、注射器类型以及储存期间的温度。然而,马动脉血气采集与分析之间可接受的延迟时间仍不明确。

假设

专用塑料注射器比多功能塑料注射器能更好地保持动脉血气的稳定性。

动物

8匹母马、1匹种马和1匹阉割公马,年龄在3至10岁之间。

方法

动脉血样本分别采集于玻璃注射器、指定用于血气采集的塑料注射器和多功能结核菌素塑料注射器中。血样在室温或冰水中储存。对于每个样本,在采集后几分钟内以及采集后5、20、30、60、90和120分钟测量动脉血氧分压(PaO2)、动脉血二氧化碳分压(PaCO2)和pH值。

结果

采集到冰水中储存的玻璃注射器中的血样,在长达117±35分钟内可提供足够的PaO2结果,而采集到任何一种塑料注射器中的血样,根据储存条件,在10±3至17±2分钟后PaO2变化>10 mmHg。保存在室温下的塑料注射器在PaCO2分析方面稳定性更好,因为它们可以储存长达83±16分钟而无显著变化。无论储存条件如何,pH值在最初一小时内变化不超过0.02。

结论及临床意义

置于冰上的玻璃注射器更适合用于PaO2分析。无论储存温度如何,采集到塑料注射器中的血液应在10分钟内进行分析,以确保PaO2值的准确性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验