酸性萃取后,采用火焰原子吸收光谱法测定多种维生素/多种矿物质剂型或片剂中的铜、铁、锰和锌。

Determination of Cu, Fe, Mn and Zn by flame atomic absorption spectrometry in multivitamin/multimineral dosage forms or tablets after an acidic extraction.

作者信息

Soriano Sílvio, Netto Annibal D Pereira, Cassella Ricardo J

机构信息

CEFET-Química, Unidade Rio de Janeiro, Brazil.

出版信息

J Pharm Biomed Anal. 2007 Jan 4;43(1):304-10. doi: 10.1016/j.jpba.2006.06.009. Epub 2006 Jul 13.

Abstract

This work presents the development of a methodology for the determination of Cu, Fe, Mn and Zn in samples of multivitamin/multimineral tablets, by flame atomic absorption spectrometry (FAAS), after extraction of the analytes with diluted hydrochloric acid solution. Several parameters that could influence the extraction process such as acid extraction solution concentration and nature, mixing mode (ultrasonic or magnetic stirring), extraction time and sample composition were evaluated. The obtained results showed that Fe, Mn and Zn were easily extracted with 1 mol/L HCl solution after 5 min of mixing with either ultrasonic or magnetic stirring for all studied samples. On the other hand, Cu extraction appeared to be more complex since it could only be extracted at the same conditions for silicate-free samples. For samples containing silicates the time of contact between solid sample and extraction solution presented remarkable influence, being necessary up to 12 h to achieve quantitative recovery with 1 mol/L HCl solution. The developed methodology was applied in the determination of Cu, Fe, Mn and Zn in seven commercially available multivitamin/multimineral tablets. The results obtained with the developed method were compared with those obtained after total digestion of samples using a closed-vessel microwave oven device.

摘要

本研究提出了一种通过火焰原子吸收光谱法(FAAS)测定多种维生素/多种矿物质片剂样品中铜、铁、锰和锌的方法,该方法是在使用稀盐酸溶液萃取分析物之后进行的。对几个可能影响萃取过程的参数进行了评估,如酸萃取溶液的浓度和性质、混合方式(超声或磁力搅拌)、萃取时间和样品组成。所得结果表明,对于所有研究的样品,在超声或磁力搅拌下混合5分钟后,铁、锰和锌很容易用1mol/L盐酸溶液萃取出来。另一方面,铜的萃取似乎更为复杂,因为只有在无硅酸盐样品的相同条件下才能萃取。对于含有硅酸盐的样品,固体样品与萃取溶液之间的接触时间有显著影响,使用1mol/L盐酸溶液达到定量回收需要长达12小时。所开发的方法应用于测定七种市售多种维生素/多种矿物质片剂中的铜、铁、锰和锌。将所开发方法得到的结果与使用密闭容器微波炉装置对样品进行完全消解后得到的结果进行了比较。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验