George Varghese A, Kishen Meera
Abacus Clinics for Contraception and Reproductive Health, Liverpool, UK.
J Fam Plann Reprod Health Care. 2006 Jul;32(3):171-2. doi: 10.1783/147118906777888378.
The Faculty of Family Planning and Reproductive Health Care (FFPRHC) has recently published Service Standards for Workload in Contraception, which state that a minimum of 20 minutes should be made available for intrauterine device/hormonal system (IUD/IUS) provision. This document acknowledges that there is currently little formal evidence relating to assessment of time taken for providing various contraceptive methods. The Abacus Clinics in Liverpool, UK provide an average of 1,300 IUD/IUS fittings in a year. We monitored the time taken for IUD/IUS provision over a 4-week period. Our study revealed that the average time taken for all types of IUD/IUS provision is significantly more than the minimum recommended by the FFPRHC.
计划生育与生殖健康护理学院(FFPRHC)最近发布了《避孕服务工作量标准》,其中规定,放置宫内节育器/激素系统(IUD/IUS)至少应留出20分钟。该文件承认,目前几乎没有关于评估提供各种避孕方法所需时间的正式证据。英国利物浦的算盘诊所每年平均放置1300例IUD/IUS。我们在4周内监测了放置IUD/IUS所需的时间。我们的研究表明,放置所有类型IUD/IUS的平均时间明显超过FFPRHC建议的最短时间。