Sellers Eric W, Krusienski Dean J, McFarland Dennis J, Vaughan Theresa M, Wolpaw Jonathan R
Laboratory of Nervous System Disorders, Wadsworth Center, New York State Department of Health, E1001 Empire State Plaza, Albany, NY 12201, USA.
Biol Psychol. 2006 Oct;73(3):242-52. doi: 10.1016/j.biopsycho.2006.04.007. Epub 2006 Jul 24.
We describe a study designed to assess properties of a P300 brain-computer interface (BCI). The BCI presents the user with a matrix containing letters and numbers. The user attends to a character to be communicated and the rows and columns of the matrix briefly intensify. Each time the attended character is intensified it serves as a rare event in an oddball sequence and it elicits a P300 response. The BCI works by detecting which character elicited a P300 response. We manipulated the size of the character matrix (either 3 x 3 or 6 x 6) and the duration of the inter stimulus interval (ISI) between intensifications (either 175 or 350 ms). Online accuracy was highest for the 3 x 3 matrix 175-ms ISI condition, while bit rate was highest for the 6 x 6 matrix 175-ms ISI condition. Average accuracy in the best condition for each subject was 88%. P300 amplitude was significantly greater for the attended stimulus and for the 6 x 6 matrix. This work demonstrates that matrix size and ISI are important variables to consider when optimizing a BCI system for individual users and that a P300-BCI can be used for effective communication.
我们描述了一项旨在评估P300脑机接口(BCI)特性的研究。该BCI向用户呈现一个包含字母和数字的矩阵。用户关注要传达的字符,矩阵的行和列会短暂增强。每次关注的字符增强时,它在一个异常刺激序列中作为罕见事件,并引发P300反应。BCI通过检测哪个字符引发了P300反应来工作。我们操纵了字符矩阵的大小(3×3或6×6)以及增强之间的刺激间隔(ISI)持续时间(175或350毫秒)。对于3×3矩阵175毫秒ISI条件,在线准确率最高,而对于6×6矩阵175毫秒ISI条件,比特率最高。每个受试者在最佳条件下的平均准确率为88%。对于关注的刺激和6×6矩阵,P300波幅显著更大。这项工作表明,在为个体用户优化BCI系统时,矩阵大小和ISI是需要考虑的重要变量,并且P300-BCI可用于有效通信。