OSCA:一种用于后囊膜混浊分析的综合开放获取系统。

OSCA: a comprehensive open-access system of analysis of posterior capsular opacification.

作者信息

Aslam Tariq M, Patton Niall, Rose Christopher J

机构信息

Princess Alexandra Eye Pavilion, Chalmers St, Edinburgh, UK.

出版信息

BMC Ophthalmol. 2006 Aug 23;6:30. doi: 10.1186/1471-2415-6-30.

Abstract

BACKGROUND

This paper presents and tests a comprehensive computerised system of analysis of digital images of posterior capsule opacification (PCO). It updates and expands significantly on a previous presentation to include facilities for selecting user defined central areas and for registering and subsequent merging of images for artefact removal. Also, the program is compiled and thus eliminates the need for specialised additional software. The system is referred to in this paper as the open-access systematic capsule assessment (OSCA). The system is designed to be evidence based, objective and openly available, improving on current systems of analysis.

METHODS

Principal features of the OSCA system of analysis are discussed. Flash artefacts are automatically located in two PCO images and the images merged to produce a composite free from these artefacts. For this to be possible the second image has to be manipulated with a registration technique to bring it into alignment with the first. Further image processing and analysis steps use a location-sensitive entropy based texture analysis of PCO. Validity of measuring PCO progression of the whole new system is assessed along with visual significance of scores. Reliability of the system is assessed.

RESULTS

Analysis of PCO by the system shows ability to detect early progression of PCO, as well as detection of more visually significant PCO. Images with no clinical PCO produce very low scores in the analysis. Reliability of the system of analysis is demonstrated.

CONCLUSION

This system of PCO analysis is evidence-based, objective and clinically useful. It incorporates flash detection and removal as well as location sensitive texture analysis. It provides features and benefits not previously available to most researchers or clinicians. Substantial evidence is provided for this system's validity and reliability.

摘要

背景

本文介绍并测试了一个用于分析后囊膜混浊(PCO)数字图像的综合计算机系统。它在之前的展示基础上进行了重大更新和扩展,包括选择用户定义的中心区域以及对图像进行配准和后续合并以去除伪影的功能。此外,该程序已编译完成,因此无需专门的额外软件。本文将该系统称为开放获取系统囊膜评估(OSCA)。该系统旨在基于证据、客观且开放可用,对当前的分析系统进行了改进。

方法

讨论了OSCA分析系统的主要特征。在两张PCO图像中自动定位闪光伪影,并将图像合并以生成一张无这些伪影的合成图像。为实现这一点,必须使用配准技术对第二张图像进行处理,使其与第一张图像对齐。进一步的图像处理和分析步骤使用基于位置敏感熵的PCO纹理分析。评估了整个新系统测量PCO进展的有效性以及分数的视觉显著性。评估了该系统的可靠性。

结果

该系统对PCO的分析显示出能够检测PCO的早期进展以及检测出更具视觉显著性的PCO。在分析中,无临床PCO的图像得分非常低。证明了分析系统的可靠性。

结论

这个PCO分析系统基于证据、客观且在临床上有用。它结合了闪光检测和去除以及位置敏感纹理分析。它提供了大多数研究人员或临床医生以前无法获得的功能和优势。为该系统的有效性和可靠性提供了大量证据。

相似文献

1
OSCA: a comprehensive open-access system of analysis of posterior capsular opacification.
BMC Ophthalmol. 2006 Aug 23;6:30. doi: 10.1186/1471-2415-6-30.
5
Correlation between the measurement of posterior capsule opacification severity and visual function testing.
J Cataract Refract Surg. 2005 Mar;31(3):534-42. doi: 10.1016/j.jcrs.2004.07.022.
6
Pentacam tomograms: a novel method for quantification of posterior capsule opacification.
Invest Ophthalmol Vis Sci. 2008 May;49(5):2004-8. doi: 10.1167/iovs.07-1056.
7
Comparison of posterior capsule opacification after two different surgical methods of cataract extraction.
Am J Ophthalmol. 2008 Mar;145(3):493-498. doi: 10.1016/j.ajo.2007.10.026. Epub 2008 Jan 16.
8
POCOman: new system for quantifying posterior capsule opacification.
J Cataract Refract Surg. 2004 Oct;30(10):2058-63. doi: 10.1016/j.jcrs.2004.05.010.
10
Three-year follow-up of posterior capsule opacification after AquaLase and NeoSoniX phacoemulsification.
Am J Ophthalmol. 2009 Sep;148(3):390-5. doi: 10.1016/j.ajo.2009.03.027. Epub 2009 May 9.

引用本文的文献

1
Evaluation of Nd:YAG Laser Capsulotomy Rates in a Real-Life Population.
Clin Ophthalmol. 2020 Oct 13;14:3249-3257. doi: 10.2147/OPTH.S276329. eCollection 2020.
2
Post-operative capsular opacification: a review.
Int J Biomed Sci. 2007 Dec;3(4):237-50.

本文引用的文献

1
Assessment of systems of analyzing PCO.
J Cataract Refract Surg. 2005 Jul;31(7):1270-1; author reply 1271-2. doi: 10.1016/j.jcrs.2005.06.028.
2
Measurement validity in ophthalmology.
Ophthalmic Epidemiol. 2005 Apr;12(2):155-61. doi: 10.1080/09286580590932752.
4
Association between intensity of posterior capsule opacification and visual acuity.
J Cataract Refract Surg. 2005 Mar;31(3):543-7. doi: 10.1016/j.jcrs.2004.05.060.
5
POCOman: new system for quantifying posterior capsule opacification.
J Cataract Refract Surg. 2004 Oct;30(10):2058-63. doi: 10.1016/j.jcrs.2004.05.010.
6
The effect of posterior capsule opacification on visual function.
Invest Ophthalmol Vis Sci. 2003 Nov;44(11):4665-9. doi: 10.1167/iovs.02-0634.
8
Posterior capsule morphology determinants of visual function.
Graefes Arch Clin Exp Ophthalmol. 2003 Mar;241(3):208-12. doi: 10.1007/s00417-003-0626-8. Epub 2003 Feb 20.
9
Comparison of 4 methods for quantifying posterior capsule opacification.
J Cataract Refract Surg. 2003 Jan;29(1):106-11. doi: 10.1016/s0886-3350(02)01509-2.
10
Removal of reflections in the photographic assessment of PCO by fusion of digital retroillumination images.
Invest Ophthalmol Vis Sci. 2003 Jan;44(1):275-80. doi: 10.1167/iovs.02-0619.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验