ten Brinke Anja, Karsten Miriam L, Dieker Miranda C, Zwaginga Jaap Jan, Vrielink Hans, Marieke van Ham S
Department of Immunopathology, Sanquin Research at CLB and Landsteiner Laboratory, Academic Medical Center, Amsterdam, The Netherlands.
Immunobiology. 2006;211(6-8):633-40. doi: 10.1016/j.imbio.2006.05.012. Epub 2006 Jul 5.
The growing number of clinical studies, using monocyte-derived DC therapy, requires protocols where a sufficient number of dendritic cell (DCs) are produced according to current Good Manufacturing Practice guidelines. Therefore, a closed culture system for the generation of DCs is inevitable. One cost-effective way to isolate monocytes directly from leukapheresis material in a closed system is by elutriation with the Elutra cell separation system. In the Elutra, granulocytes co-purify with the monocytes. Therefore, we studied if and to what extent the presence of granulocytes in a monocyte product affects the generation of mature DCs. The presence of up to 16% granulocytes in the monocyte product had no significant effects on the quality of the DCs formed. The presence of higher granulocyte percentages, however, gradually altered DC quality. In this respect, the presence of higher number of granulocytes induced significant lower migratory capacity of the DCs and lower expression levels of CD80, CD40 and CD86. No effects were observed on the DC yield, cytokine production or the stimulatory capacity of the DCs in MLR. In conclusion, the presence of 20-30% granulocytes in a monocyte product has no major influence on the quality of the DCs generated from monocytes. Therefore, the Elutra is a suitable closed system apparatus to separate monocytes from other blood components for the generation of DCs, even from leukapheresis material which contains a high number of granulocytes.
越来越多使用单核细胞衍生树突状细胞疗法的临床研究,需要按照现行药品生产质量管理规范指南生成足够数量树突状细胞(DCs)的方案。因此,用于生成DCs的封闭培养系统是必不可少的。在封闭系统中直接从白细胞分离材料中分离单核细胞的一种经济有效的方法是使用Elutra细胞分离系统进行淘洗。在Elutra中,粒细胞与单核细胞共同纯化。因此,我们研究了单核细胞产品中粒细胞的存在是否以及在何种程度上会影响成熟DCs的生成。单核细胞产品中存在高达16%的粒细胞对所形成DCs的质量没有显著影响。然而,更高百分比粒细胞的存在会逐渐改变DCs的质量。在这方面,更高数量粒细胞的存在会导致DCs的迁移能力显著降低以及CD80、CD40和CD86的表达水平降低。在混合淋巴细胞反应中,未观察到对DCs产量、细胞因子产生或刺激能力的影响。总之,单核细胞产品中存在20 - 30%的粒细胞对由单核细胞生成的DCs质量没有重大影响。因此,Elutra是一种合适的封闭系统设备,可用于从其他血液成分中分离单核细胞以生成DCs,即使是从含有大量粒细胞的白细胞分离材料中分离也适用。