Suppr超能文献

采用额外刺激技术测量的两次训练间暂停对心室有效不应期的影响。

Effect of the intertrain pause on the ventricular effective refractory period measured by the extrastimulus technique.

作者信息

Morady F, Kadish A H, Rosenheck S, Schmaltz S, Debuitleir M

机构信息

Division of Cardiology, University of Michigan Medical Center, Ann Arbor 48109-0022.

出版信息

Pacing Clin Electrophysiol. 1990 Apr;13(4):405-9. doi: 10.1111/j.1540-8159.1990.tb02054.x.

Abstract

This study determined the effect of the duration of the intertrain pause on the ventricular effective refractory period (VERP) measured by the extrastimulus technique using conventional eight-beat basic drive trains. In 50 subjects, the VERP was measured using a basic drive train cycle length of 500 msec, 2-msec steps in the extrastimulus coupling interval, and intertrain pauses of 0, 1, 4, 8, 20, 40, 60, or 180 seconds. The VERP increased significantly with each stepwise increment in the intertrain pause up to 20 seconds, then reached a plateau. The VERP measured with an intertrain pause of 20 seconds was a mean of 13 msec longer than when measured with a conventional 4-second pause. The results of this study demonstrate a direct relationship between the VERP and the duration of the pause separating the eight-beat basic drive trains used to measure the VERP. When the cycle length of the basic drive train is 500 msec, the VERP lengthens as the duration of the intertrain pause increases from 1 to 20 seconds, demonstrating that the basic drive trains exert a cumulative effect on the VERP when the intertrain pause is shorter than 20 seconds. A cumulative effect of the basic drive trains on the VERP is lost when the intertrain pause is 20 seconds or more.

摘要

本研究采用传统的八次搏动基础驱动序列,通过额外刺激技术测定了两次训练间暂停时长对心室有效不应期(VERP)的影响。在50名受试者中,使用500毫秒的基础驱动序列周期长度、额外刺激耦合间期以2毫秒步长变化,以及0、1、4、8、20、40、60或180秒的两次训练间暂停来测量VERP。随着两次训练间暂停逐步增加至20秒,VERP显著增加,然后达到平台期。与传统4秒暂停相比,20秒两次训练间暂停测量的VERP平均长13毫秒。本研究结果表明,VERP与用于测量VERP的八次搏动基础驱动序列之间的暂停时长存在直接关系。当基础驱动序列的周期长度为500毫秒时,随着两次训练间暂停时长从1秒增加到20秒,VERP延长,这表明当两次训练间暂停短于20秒时,基础驱动序列对VERP产生累积效应。当两次训练间暂停为20秒或更长时,基础驱动序列对VERP的累积效应消失。

相似文献

3
The maximum effect of an increase in rate on human ventricular refractoriness.
Pacing Clin Electrophysiol. 1988 Dec;11(12):2223-34. doi: 10.1111/j.1540-8159.1988.tb05989.x.
5
The effect of rate on prolongation of ventricular refractoriness by quinidine in humans.奎尼丁对人体心室不应期延长的速率影响。
Pacing Clin Electrophysiol. 1990 Nov;13(11 Pt 1):1379-84. doi: 10.1111/j.1540-8159.1990.tb04012.x.
9
Monophasic action potential duration during programmed electrical stimulation.程序性电刺激期间的单相动作电位持续时间。
Pacing Clin Electrophysiol. 1991 Jun;14(6):1049-59. doi: 10.1111/j.1540-8159.1991.tb04156.x.