Sporer Scott M, Paprosky Wayne G
Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA.
J Arthroplasty. 2006 Sep;21(6 Suppl 2):83-6. doi: 10.1016/j.arth.2006.05.008.
Stable acetabular fixation cannot be reliably achieved with the use of a hemispherical porous coated component alone in patients with a Paprosky type IIIa defect. The purpose of the present study was to determine the short-term results of a tantalum porous coated hemispherical acetabular component supported with a modular tantalum augment in Paprosky type IIIa defects. A total of 28 patients (28 hips) were treated for a type IIIa acetabular defect between 2001 and 2003 with the use of a trabecular metal acetabular component supported with a modular, superiorly placed trabecular metal augment. At an average of 3.1 years follow-up, 1 patient required rerevision for recurrent instability. The remaining hips remain radiographically stable. Clinically, the patients' modified Postel Merle d'Aubigne score improved from 6.8 preoperatively to 10.6 postoperatively. The use of a trabecular metal acetabular component with a superiorly placed trabecular metal augment demonstrates encouraging short-term results for Paprosky type IIIa acetabular defects.
对于Paprosky IIIa型缺损的患者,仅使用半球形多孔涂层假体无法可靠地实现髋臼的稳定固定。本研究的目的是确定在Paprosky IIIa型缺损中使用模块化钽增强支撑的钽多孔涂层半球形髋臼假体的短期结果。2001年至2003年间,共有28例患者(28髋)接受了IIIa型髋臼缺损治疗,使用了由模块化、高位放置的小梁金属增强支撑的小梁金属髋臼假体。平均随访3.1年时,1例患者因复发性不稳定需要再次翻修。其余髋关节在影像学上保持稳定。临床上,患者改良的Postel Merle d'Aubigne评分从术前的6.8分提高到术后的10.6分。使用高位放置小梁金属增强的小梁金属髋臼假体对Paprosky IIIa型髋臼缺损显示出令人鼓舞的短期结果。