Suppr超能文献

与内侧间室单髁关节置换翻修相关的患者、植入物及对线因素。

Patient, implant, and alignment factors associated with revision of medial compartment unicondylar arthroplasty.

作者信息

Collier Matthew B, Eickmann Thomas H, Sukezaki Fumio, McAuley James P, Engh Gerard A

机构信息

Anderson Orthopaedic Research Institute, Alexandria, VA, USA.

出版信息

J Arthroplasty. 2006 Sep;21(6 Suppl 2):108-15. doi: 10.1016/j.arth.2006.04.012.

Abstract

The investigators reviewed 245 fixed-bearing unicondylar arthroplasties that one surgeon performed as treatment of medial compartment osteoarthritis between 1988 and 1997 using a variety of cemented metal-backed tibial components and gamma-irradiated-in-air polyethylene bearings. Multivariate statistical analysis was used to evaluate how the event of revision was influenced by 3 patient factors, 3 implant factors, and 7 factors assessed from preoperative and early postoperative radiographs. Five factors were statistically associated with revision: (younger) patient age, (thinner) tibial component initial thickness, (longer) polyethylene shelf age, (lesser) angular reduction of medial tibial plateau varus, and (more varus) postoperative hip-knee-ankle angle. Besides illustrating deleterious consequences of using gamma-irradiated-in-air polyethylene in medial unicompartmental arthroplasty, our results support reducing varus angulation of the medial tibial plateau and knee at surgery.

摘要

研究人员回顾了一位外科医生在1988年至1997年间使用多种骨水泥固定金属背衬胫骨组件和空气中伽马射线辐照的聚乙烯轴承,对245例内侧间室骨关节炎患者实施的固定平台单髁关节置换术。采用多变量统计分析来评估翻修事件如何受到3个患者因素、3个植入物因素以及术前和术后早期X线片评估的7个因素的影响。有5个因素与翻修在统计学上相关:(年轻的)患者年龄、(较薄的)胫骨组件初始厚度、(较长的)聚乙烯衬垫使用时间、(较小的)内侧胫骨平台内翻角度矫正以及(更大内翻的)术后髋-膝-踝角。除了说明在内侧单髁关节置换术中使用空气中伽马射线辐照聚乙烯的有害后果外,我们的结果支持在手术中减少内侧胫骨平台和膝关节的内翻角度。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验