OBJECTIVE

The aim of this study was to evaluate the diagnostic value of time-resolved contrast-enhanced MR angiography in adults with congenital heart disease.

SUBJECTS AND METHODS

Twenty patients with congenital heart disease (mean age, 38 +/- 14 years; range, 16-73 years) underwent contrast-enhanced turbo fast low-angle shot MR angiography. Thirty consecutive coronal 3D slabs with a frame rate of 1-second duration were acquired. The mask defined as the first data set was subtracted from subsequent images. Image quality was evaluated using a 5-point scale (from 1, not assessable, to 5, excellent image quality). Twelve diagnostic parameters yielded 1 point each in case of correct diagnosis (binary analysis into normal or abnormal) and were summarized into three categories: anatomy of the main thoracic vessels (maximum, 5 points), sequential cardiac anatomy (maximum, 5 points), and shunt detection (maximum, 2 points). The results were compared with a combined clinical reference comprising medical or surgical reports and other imaging studies. Diagnostic accuracies were calculated for each of the parameters as well as for the three categories.

RESULTS

The mean image quality was 3.7 +/- 1.0. Using a binary approach, 220 (92%) of the 240 single diagnostic parameters could be analyzed. The percentage of maximum diagnostic points, the sensitivity, the specificity, and the positive and the negative predictive values were all 100% for the anatomy of the main thoracic vessels; 97%, 87%, 100%, 100%, and 96% for sequential cardiac anatomy; and 93%, 93%, 92%, 88%, and 96% for shunt detection.

CONCLUSION

Time-resolved contrast-enhanced MR angiography provides, in one breath-hold, anatomic and qualitative functional information in adult patients with congenital heart disease. The high diagnostic accuracy allows the investigator to tailor subsequent specific MR sequences within the same session.

摘要

目的

本研究旨在评估时间分辨对比增强磁共振血管造影对成人先天性心脏病的诊断价值。

对象与方法

20例先天性心脏病患者(平均年龄38±14岁;范围16 - 73岁)接受了对比增强快速低角度激发磁共振血管造影检查。连续采集30个冠状面三维层面,帧率为1秒。将定义为第一组数据集的蒙片从后续图像中减去。图像质量采用5分制进行评估(从1分,不可评估,到5分,图像质量极佳)。12个诊断参数在正确诊断(分为正常或异常的二元分析)时各得1分,并归纳为三类:主要胸部血管解剖(最高5分)、连续心脏解剖(最高5分)和分流检测(最高2分)。结果与包含医学或外科报告及其他影像学检查的综合临床参考进行比较。计算每个参数以及三类参数的诊断准确性。

结果

平均图像质量为3.7±1.0。采用二元方法,240个单一诊断参数中的220个(92%)可进行分析。主要胸部血管解剖的最大诊断分数百分比、敏感性、特异性、阳性和阴性预测值均为100%;连续心脏解剖的分别为97%、87%、100%、100%和96%;分流检测的分别为93%、93%、92%、88%和96%。

结论

时间分辨对比增强磁共振血管造影在一次屏气过程中就能为成人先天性心脏病患者提供解剖和定性功能信息。高诊断准确性使研究者能够在同一次检查中定制后续特定的磁共振序列。