Electromagnetic interference in patients with implanted cardioverter-defibrillators and implantable loop recorders.

作者信息

de Sousa Marcos, Klein Gunnar, Korte Thomas, Niehaus Michael

机构信息

Department of Cardiology and Angiology, Medical School Hannover, Germany.

出版信息

Indian Pacing Electrophysiol J. 2002 Jul 1;2(3):79-84.

Abstract
摘要

相似文献

4
The safety of electrical stimulation in patients with pacemakers and implantable cardioverter defibrillators: A systematic review.
J Rehabil Assist Technol Eng. 2017 Dec 5;4:2055668317745498. doi: 10.1177/2055668317745498. eCollection 2017 Jan-Dec.
5
Are Contemporary Smartwatches and Mobile Phones Safe for Patients With Cardiovascular Implantable Electronic Devices?
JACC Clin Electrophysiol. 2020 Sep;6(9):1158-1166. doi: 10.1016/j.jacep.2020.04.033. Epub 2020 Jul 29.
8
Implantable rhythm devices and electromagnetic interference: myth or reality?
Expert Rev Cardiovasc Ther. 2008 Jul;6(6):823-32. doi: 10.1586/14779072.6.6.823.
9
Risk of electromagnetic interference induced by dental equipment on cardiac implantable electrical devices.
Eur J Oral Sci. 2016 Dec;124(6):559-565. doi: 10.1111/eos.12313. Epub 2016 Oct 17.
10
Electromagnetic interference of avalanche transceivers with cardiac pacemakers and implantable cardioverter defibrillators.
Pacing Clin Electrophysiol. 2013 Aug;36(8):931-8. doi: 10.1111/pace.12159. Epub 2013 May 21.

引用本文的文献

1
New-generation electronic appliances and cardiac implantable electronic devices: a systematic literature review of mechanisms and in vivo studies.
J Interv Card Electrophysiol. 2024 Oct;67(7):1709-1720. doi: 10.1007/s10840-024-01777-z. Epub 2024 Mar 5.
2
A Review and Analysis of Managing Commonly Seen Implanted Devices for Patients Undergoing Radiation Therapy.
Adv Radiat Oncol. 2021 Aug 6;6(4):100732. doi: 10.1016/j.adro.2021.100732. eCollection 2021 Jul-Aug.
5

本文引用的文献

1
Interference of two common European digital cellular phones with implantable cardioverter-defibrillators.
Eur Heart J. 2002 Apr;23(7):586-8; dicussion 588. doi: 10.1053/euhj.2001.3013.
2
Electromagnetic interference of an implantable loop recorder by commonly encountered electronic devices.
Pacing Clin Electrophysiol. 2000 Oct;23(10 Pt 1):1516-8. doi: 10.1046/j.1460-9592.2000.01516.x.
3
MR imaging and cardiac pacemakers: in-vitro evaluation and in-vivo studies in 51 patients at 0.5 T.
Radiology. 2000 Jun;215(3):869-79. doi: 10.1148/radiology.215.3.r00jn08869.
4
Implantable cardioverter defibrillators and cellular telephones: is there any interference?
Pacing Clin Electrophysiol. 1999 Jul;22(7):983-9. doi: 10.1111/j.1540-8159.1999.tb00561.x.
5
Interactions between electronic article surveillance systems and implantable cardioverter-defibrillators.
Circulation. 1999 Jul 27;100(4):387-92. doi: 10.1161/01.cir.100.4.387.
7
[Electromagnetic interference between automatic defibrillators and digital and analog cellular telephones].
Rev Esp Cardiol. 1998 May;51(5):375-82. doi: 10.1016/s0300-8932(98)74761-x.
8
Influence of digital and analogue cellular telephones on implanted pacemakers.
Eur Heart J. 1997 Oct;18(10):1632-41. doi: 10.1093/oxfordjournals.eurheartj.a015144.
9
Electromagnetic interference of pacemakers by mobile phones.
Pacing Clin Electrophysiol. 1996 Oct;19(10):1431-46. doi: 10.1111/j.1540-8159.1996.tb03155.x.
10
State of the science: pacemaker and defibrillator interference from wireless communication devices.
Pacing Clin Electrophysiol. 1996 Oct;19(10):1419-30. doi: 10.1111/j.1540-8159.1996.tb03154.x.