Suppr超能文献

术前抽吸在感染性人工膝关节诊断中的价值:一项回顾性研究及文献综述

The value of pre-operative aspiration in the diagnosis of an infected prosthetic knee: a retrospective study and review of literature.

作者信息

Van den Bekerom Michel P J, Stuyck José

机构信息

Department of Orthopaedic Surgery, Gelre Hospitals, Apeldoorn, the Netherlands.

出版信息

Acta Orthop Belg. 2006 Aug;72(4):441-7.

Abstract

The purpose of this study was to compare the results of cultures of preoperative aspiration samples with those of swabs taken intra-operatively. The records of 70 revision arthroplasties of the knee from 69 patients, 49 females and 20 males, were reviewed. The mean age of the patients at time of revision arthroplasty was 67 years (range: 34 to 89). Sixty-eight knees from 67 patients were included. There were 32 true positives, 17 true negatives, 6 false positives and 13 false negatives. This led to a specificity, sensitivity and accuracy of 57%, 84% and 72%, respectively. Based on these findings, pre-operative aspiration has a positive predictive value of 71% and a negative predictive value of 74%. When the aspiration sample yields a positive culture, the chances are high that the prosthetic knee is infected. When aspiration is negative, infection cannot be ruled out. Our study suggests that, in such cases, a coagulase negative Staphylococcus (CNS) infection has to be considered.

摘要

本研究的目的是比较术前抽吸样本培养结果与术中拭子培养结果。回顾了69例患者(49例女性和20例男性)的70例膝关节翻修置换术记录。翻修置换术时患者的平均年龄为67岁(范围:34至89岁)。纳入了67例患者的68个膝关节。有32例假阳性、17例假阴性、6例假阳性和13例假阴性。这导致特异性、敏感性和准确性分别为57%、84%和72%。基于这些发现,术前抽吸的阳性预测值为71%,阴性预测值为74%。当抽吸样本培养结果为阳性时,人工膝关节感染的可能性很高。当抽吸结果为阴性时,不能排除感染。我们的研究表明,在这种情况下,必须考虑凝固酶阴性葡萄球菌(CNS)感染。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验