Suppr超能文献

快速气相色谱/质谱法测定人尿中的利尿剂和掩蔽剂:用于反兴奋剂分析的高效筛查方案的开发与验证

Fast gas chromatographic/mass spectrometric determination of diuretics and masking agents in human urine: Development and validation of a productive screening protocol for antidoping analysis.

作者信息

Morra V, Davit P, Capra P, Vincenti M, Di Stilo A, Botrè F

机构信息

Consorzio Piemontese per la Prevenzione e Repressione del Doping e di altri Usi Illeciti dei Farmaci, Regione Gonzole 10, 10043 Orbassano, Turin, Italy.

出版信息

J Chromatogr A. 2006 Dec 1;1135(2):219-29. doi: 10.1016/j.chroma.2006.09.034. Epub 2006 Oct 5.

Abstract

An analytical procedure was developed for the fast screening of 16 diuretics (acetazolamide, althiazide, amiloride, bendroflumethiazide, bumetanide, canrenoic acid, chlorthalidone, chlorthiazide, clopamide, ethacrynic acid, furosemide, hydrochlorthiazide, hydroflumethiazide, indapamide, triamterene, trichlormethiazide) and a masking agent (probenecid) in human urine. The whole method involves three analytical steps, including (1) liquid/liquid extraction of the analytes from the matrix, (2) their reaction with methyl iodide at 70 degrees C for 2 h to form methyl derivatives, (3) analysis of the resulting mixture by fast gas chromatography/electron impact mass spectrometry (fast GC/EI-MS). The analytical method was validated by determining selectivity, linearity, accuracy, intra and inter assay precision, extraction efficiencies and signal to noise ratio (S/N) at the lowest calibration level (LCL) for all candidate analytes. The analytical performances of three extraction procedures and five combination of derivatization parameters were compared in order to probe the conditions for speeding up the sample preparation step. Limits of detection (LOD) were evaluated in both EI-MS and ECNI-MS (electron capture negative ionization mass spectrometry) modes, indicating better sensitivity for most of the analytes using the latter ionization technique. The use of short columns and high carrier gas velocity in fast GC/MS produced efficient separation of the analytes in less than 4 min, resulting in a drastic reduction of the analysis time, while a resolution comparable to that obtained from classic GC conditions is maintained. Fast quadrupole MS electronics allows high scan rates and effective data acquisition both in scan and selected ion monitoring modes.

摘要

开发了一种分析方法,用于快速筛查人尿中的16种利尿剂(乙酰唑胺、阿噻嗪、阿米洛利、苄氟噻嗪、布美他尼、坎利酮酸、氯噻酮、氯噻嗪、氯帕胺、依他尼酸、呋塞米、氢氯噻嗪、氢氟噻嗪、吲达帕胺、氨苯蝶啶、三氯噻嗪)和一种掩蔽剂(丙磺舒)。整个方法包括三个分析步骤,即:(1) 从基质中液/液萃取分析物;(2) 分析物在70℃下与碘甲烷反应2小时以形成甲基衍生物;(3) 通过快速气相色谱/电子轰击质谱法(快速GC/EI-MS)分析所得混合物。通过测定所有候选分析物在最低校准水平(LCL)下的选择性、线性、准确度、批内和批间精密度、萃取效率以及信噪比(S/N),对该分析方法进行了验证。比较了三种萃取程序和五种衍生化参数组合的分析性能,以探索加快样品制备步骤的条件。在EI-MS和ECNI-MS(电子捕获负电离质谱法)模式下评估了检测限(LOD),结果表明使用后一种电离技术时,大多数分析物具有更好的灵敏度。在快速GC/MS中使用短柱和高载气速度可在不到4分钟的时间内实现分析物的高效分离,从而大幅缩短分析时间,同时保持与经典GC条件相当的分离度。快速四极杆MS电子设备允许在扫描和选择离子监测模式下实现高扫描速率和有效的数据采集。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验