Ikem Innocent C, Ogunlusi Johnson D, Ine Henry R
Department of Orthopaedic Surgery and Traumatology, College of Health Sciences, Obafemi Awolowo University, Ile-Ife, Osun State, Nigeria.
Int Orthop. 2007 Aug;31(4):487-90. doi: 10.1007/s00264-006-0219-3. Epub 2006 Oct 13.
Interlocking nails are commonly performed using an image intensifier. These are expensive and are not readily available in most resource-poor countries of the world. The aim of this study was to achieve interlocking nailing without the use of an image intensifier. This is a prospective descriptive analysis of 40 consecutive cases seen with shaft fractures of the humerus, femur, and tibia. Fracture fixation was done using Surgical Implant Generation Network (SIGN) nails. Forty limbs in 34 patients were studied. There were 12 females and 22 males, giving a ratio of 1:2. The mean age (years) was 35.75+/-13.16 and the range was 17-70 years. The studied bones were: humerus 10%, femur 65%, and tibia 25%. The fracture lines were: transverse 40%, oblique 15%, and communited 45%. Fracture grades were: closed 90%, grade I, 5%, grade II, 2.5%, and grade IIIA, 2.5%. Surgical approaches were: antegrade 62.5% and retrograde 37.5%. Indications for fixation were: recent fracture 92.5%, non-union 5%, and malunion 3%. Methods of reductions were: open 85% and closed 15%. The mean follow-up period (years) was 1.50+/-0.78. The union time averaged 3 months. Complication was mainly screw loosening due to severe osteoporoses in one case. It is, therefore, concluded that, with the aid of external jigs and slot finders, interlocking can be achieved without an image intensifier.
交锁髓内钉通常在影像增强器辅助下进行操作。这些设备价格昂贵,在世界上大多数资源匮乏的国家并不容易获得。本研究的目的是在不使用影像增强器的情况下实现交锁髓内钉固定。这是一项对40例肱骨干、股骨干和胫骨干骨折患者的前瞻性描述性分析。骨折固定采用外科植入物生成网络(SIGN)髓内钉。研究了34例患者的40条肢体。其中女性12例,男性22例,男女比例为1:2。平均年龄(岁)为35.75±13.16,年龄范围为17 - 70岁。所研究的骨骼分布为:肱骨10%,股骨65%,胫骨25%。骨折线类型为:横行40%,斜行15%,粉碎性45%。骨折分级为:闭合性90%,I级5%,II级2.5%,IIIA级2.5%。手术入路为:顺行62.5%,逆行37.5%。固定指征为:新鲜骨折92.5%,骨不连5%,畸形愈合3%。复位方法为:切开复位85%,闭合复位15%。平均随访时间(年)为1.50±0.78。骨折愈合时间平均为3个月。并发症主要为1例因严重骨质疏松导致的螺钉松动。因此,得出结论:借助外部夹具和槽形定位器,无需影像增强器即可实现交锁髓内钉固定。