Suppr超能文献

“杂交迷宫”手术中期结果:双极射频与冷冻消融联合用于心房颤动的外科治疗

Mid-term results of the 'hybrid maze': a combination of bipolar radiofrequency and cryoablation for surgical treatment of atrial fibrillation.

作者信息

Sternik Leonid, Ghosh Probal, Luria David, Glikson Michael, Shpigelshtein Daniel, Malachy Ateret, Raanani Ehud

机构信息

Department of Cardiac Surgery, Sheba Medical Center, Israel.

出版信息

J Heart Valve Dis. 2006 Sep;15(5):664-70.

Abstract

BACKGROUND AND AIM OF THE STUDY

Although the use of new sources of energy for the ablation of atrial fibrillation (AF) has simplified the procedure, concerns have been expressed with regard to the safety and efficacy of the various devices. Herein are described the results of a technique using a combination of bipolar radiofrequency (RF) and cryoablation.

METHODS

Between February 2004 and August 2005, the combined procedure was used on 60 patients, 32 of whom (54%) had persistent AF, and 28 (46%) permanent AF. Lesions set similar to the Maze III procedure were used, with the addition of a right atrial isthmus lesion in the area of the coronary sinus and without right atrial appendage amputation and septal lesion.

RESULTS

There were no operative complications and no death or major morbidity. The mean duration of the ablation procedure was 30 min (range: 27-36 min) for biatrial procedures, and 16 min (range: 15-19 min) for left atrial procedures. Forty-two patients (70%) were discharged in sinus rhythm. On completion of follow up, 48 patients (80%) were in sinus rhythm. Among 45 patients treated with cryoablation rather than monopolar RF, 89% were in sinus rhythm at the mean follow up of nine months. The predictor for recurrent post-procedural AF was preoperative permanent AF for more than 10 years' duration (p = 0.039), while that for postoperative atypical flutter was use of the monopolar RF ablator rather than the cryoablator (p = 0.001).

CONCLUSION

The use of a bipolar RF device with the cryoprobe is an appealing combination which enables the Maze III lesion set to be completed in a straightforward, safe, and efficient manner.

摘要

研究背景与目的

尽管使用新能源进行心房颤动(AF)消融简化了手术过程,但人们对各种设备的安全性和有效性仍存在担忧。本文介绍了一种联合使用双极射频(RF)和冷冻消融技术的结果。

方法

2004年2月至2005年8月期间,60例患者接受了联合手术,其中32例(54%)为持续性AF,28例(46%)为永久性AF。采用了与迷宫III手术相似的病变设置,在冠状窦区域增加了右心房峡部病变,未进行右心耳切除和房间隔病变。

结果

无手术并发症,无死亡或严重并发症。双心房手术的平均消融时间为30分钟(范围:27 - 36分钟),左心房手术为16分钟(范围:15 - 19分钟)。42例患者(70%)出院时为窦性心律。随访结束时,48例患者(80%)为窦性心律。在45例接受冷冻消融而非单极RF治疗的患者中,平均随访9个月时,89%为窦性心律。术后AF复发的预测因素是术前永久性AF持续超过10年(p = 0.039),而术后非典型房扑的预测因素是使用单极RF消融器而非冷冻消融器(p = 0.001)。

结论

双极RF设备与冷冻探头联合使用是一种有吸引力的组合,能够以直接、安全和有效的方式完成迷宫III病变设置。