• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Plasma ANP and renin-angiotensin-aldosterone system as new parameters describing the hemodynamics of the circulatory system after implantation of stented or stentless aortic valves.

作者信息

Szafranek Adam, Jasinski Marek, Kolowca Maciej, Gemel Marek, Wos Stanislaw

机构信息

Department of Cardiac Surgery, University Hospital of Wales, Cardiff, UK.

出版信息

J Heart Valve Dis. 2006 Sep;15(5):702-8; discussion 709.

PMID:17044378
Abstract

BACKGROUND AND AIM OF THE STUDY

Aortic valve replacement (AVR) in patients with a small aortic root involves the occurrence of patient-prosthesis mismatch (PPM). Recent reports have shown that a reduced effective orifice area index (EOAI) may not be the sole factor responsible for this complication. The study aim was to analyze the activity of atrial natriuretic peptide (ANP)/renin-angiotensin-aldosterone (RAA) after implantation of stented or stentless valves.

METHODS

Between 2001 and 2003, a total of 30 patients operated on at the authors' institution received either a stentless Freestyle bioprosthesis (group A; n = 15) or a stented Mosaic bioprosthesis (group B; n = 15). The demographics of both groups were similar, and all patients underwent echocardiography preoperatively, and at one, six and 12 months postoperatively. The activity of the RAA system and plasma ANP level were measured in all patients preoperatively and at one and six months postoperatively.

RESULTS

At one month after AVR, statistically significant inter-group differences were noted in plasma renin activity (group A, 3.7 +/- 2.1 ng/ml/h; group B, 5.6 +/- 0.8 ng/ml/h; p <0.05; control value 0.3-5.3 ng/ml/h). For ANP, statistically significant differences were present at one month after surgery (group A, 36.3 +/- 5.1 pg/ml; group B, 62.9 +/- 9.2 pg/ml; p <0.005; control value 27.3-37.2 pg/ml). On echocardiography, the ejection fraction, aortic valve gradient, EOAI and left ventricular mass index (LVMI) were assessed. A statistically significant difference was identified for the LVMI at 12 months postoperatively (group A, 216 +/- 13 g/m2; group B, 240 +/- 18 g/m2; p <0.05). In terms of other parameters both groups were similar.

CONCLUSION

The implantation of an aortic valve prosthesis affects the hemodynamics of the entire circulatory system, and thus the activity of natriuretic systems. Whilst stentless valves allowed much more rapid normalization of circulatory system hemodynamics (one month), no difference compared to preoperative was identified after six months. Natriuretic peptides appear to provide more sensitive (long-term) but less specific (short-term) assessment of circulatory system behavior than echocardiography.

摘要

相似文献

1
Plasma ANP and renin-angiotensin-aldosterone system as new parameters describing the hemodynamics of the circulatory system after implantation of stented or stentless aortic valves.
J Heart Valve Dis. 2006 Sep;15(5):702-8; discussion 709.
2
The Toronto root stentless valve in the subcoronary position is hemodynamically superior to the mosaic stented completely supra-annular bioprosthesis.置于冠状动脉下位置的多伦多无支架瓣膜在血流动力学上优于镶嵌式带支架完全瓣环上生物假体。
J Heart Valve Dis. 2005 Nov;14(6):814-21; discussion 821.
3
Stentless and stented aortic valve replacement in elderly patients: Factors affecting midterm clinical and hemodynamical outcome.老年患者的无支架和带支架主动脉瓣置换术:影响中期临床和血流动力学结果的因素。
Eur J Cardiothorac Surg. 2006 Nov;30(5):706-13. doi: 10.1016/j.ejcts.2006.07.017. Epub 2006 Sep 6.
4
Aortic valve replacement with new-generation stentless pericardial valves: short-term clinical and hemodynamic results.新一代无支架心包瓣膜置换主动脉瓣:短期临床和血流动力学结果。
J Heart Valve Dis. 2005 Sep;14(5):623-9.
5
Early hemodynamic evaluation of Trifecta and Freestyle bioprostheses in patients with a small aortic root: preliminary results from a prospective randomized study.小主动脉根部患者使用Trifecta和Freestyle生物瓣膜的早期血流动力学评估:一项前瞻性随机研究的初步结果
J Heart Valve Dis. 2014 Sep;23(5):633-41.
6
Stentless vs. stented aortic valve bioprostheses: a prospective randomized controlled trial.
Eur Heart J. 2007 Oct;28(19):2369-74. doi: 10.1093/eurheartj/ehm327. Epub 2007 Aug 1.
7
Efficacy of Stentless Aortic Bioprosthesis Implantation for Aortic Stenosis with Small Aortic Annulus.无支架生物主动脉瓣置换术治疗小主动脉瓣环主动脉瓣狭窄的疗效
Thorac Cardiovasc Surg. 2015 Sep;63(6):446-51. doi: 10.1055/s-0034-1389106. Epub 2014 Sep 5.
8
Prospective randomized evaluation of stentless vs. stented aortic biologic prosthetic valves in the elderly at five years.老年患者无支架与带支架主动脉生物人工瓣膜五年前瞻性随机评估。
Interact Cardiovasc Thorac Surg. 2009 Apr;8(4):449-53. doi: 10.1510/icvts.2008.181362. Epub 2009 Jan 6.
9
Impact of patient-prosthesis mismatch and aortic valve design on coronary flow reserve after aortic valve replacement.人工瓣膜与患者不匹配及主动脉瓣设计对主动脉瓣置换术后冠状动脉血流储备的影响。
J Am Coll Cardiol. 2007 Feb 20;49(7):790-6. doi: 10.1016/j.jacc.2006.10.052. Epub 2007 Feb 5.
10
Patient-prosthesis mismatch and left ventricular remodelling after implantation of Shelhigh SuperStentless aortic valve prostheses.植入Shelhigh SuperStentless主动脉瓣假体后的患者-假体不匹配与左心室重塑
J Cardiovasc Surg (Torino). 2008 Aug;49(4):539-43.