The electrochemical behavior of glipizide at the hanging mercury drop electrode (HMDE) was studied in B-R universal buffers of pH 1.7-11. The voltammograms exhibited a well-defined 4-electron irreversible cathodic peak which attributed to reduction of the two C=N of the pyrazine ring of glipizide molecule. Glipizide was found to has an interfacial adsorptive character onto the mercury electrode surface. A monolayer surface coverage of 1.02x10(-10)mol cm(-2) was estimated and hence each adsorbed glipizide molecule occupied an area of 1.63 nm(2) onto the mercury electrode surface. A simple and precise square-wave adsorptive cathodic stripping (SWAdCS) voltammetric procedure was described for quantification of bulk glipizide with a limit of detection of 1.5x10(-10)M and a limit of quantitation of 5x10(-10)M. The proposed procedure was successfully applied for quantitation of glipizide in its pharmaceutical formulation (Minidiab tablets) without interference from excipients.