Thaunat Mathieu, Chambat Pierre
Orthopaedic Surgery Department, Centre Orthopedique Santy, 24, Avenue Paul Santy, 69008, Lyon, France,
Knee Surg Sports Traumatol Arthrosc. 2007 May;15(5):522-4. doi: 10.1007/s00167-006-0218-3. Epub 2006 Nov 11.
We report a case of subcutaneous pretibial ganglion, with direct communication to the tibial tunnel after an autologous reconstruction of the anterior cruciate ligament with hamstring tendons. The tibial graft fixation was with a 9 mm poly-L-lactide interference screw 5 years earlier. The screw had undergone complete resorption at the time the cyst occurred. No joint inflammatory reaction or graft insufficiency was detected. The patient underwent cyst excision and curettage of the tibial tunnel with full recovery. This complication seems to be the consequence of a direct communication between the joint and the pretibial subcutaneous tissue through a fibrous tibial tunnel and would have occurred, as there is no full osteointegration of the graft due to the resorption of the bioabsorbable interference screw.
我们报告一例胫骨前皮下腱鞘囊肿病例,该囊肿在自体腘绳肌腱重建前交叉韧带后与胫骨隧道直接相通。5年前采用9毫米聚-L-丙交酯干涉螺钉固定胫骨移植物。囊肿出现时,螺钉已完全吸收。未检测到关节炎症反应或移植物功能不全。患者接受了囊肿切除及胫骨隧道刮除术,术后完全康复。这种并发症似乎是由于关节与胫骨前皮下组织通过纤维性胫骨隧道直接相通所致,并且由于生物可吸收干涉螺钉的吸收导致移植物未完全骨整合,所以才会发生这种情况。