On-site infiltration of a copper roof runoff may contribute to deterioration of the ground and ground water. To avoid such a negative effect the performance of two different technical systems, equipped with four different barrier materials, regarding copper elimination was examined in a field study. During the period March 2004 to January 2005, 16 rain events were examined. Copper concentrations between 200 and 11,000 microg/L in the roof runoff during a rain event were observed. The cover material of the roof and the drainage system were responsible for the high concentrations of copper in the roof runoff. It was evident that roof aspects facing towards the wind direction were receiving higher rainfall, thus were establishing higher copper runoff rates. The retention facilities have reached a performance of up to 97% regarding copper elimination.

摘要

铜质屋顶径流的现场渗入可能会导致地面和地下水恶化。为避免这种负面影响,在一项实地研究中,对配备四种不同阻隔材料的两种不同技术系统在去除铜方面的性能进行了检测。在2004年3月至2005年1月期间,对16次降雨事件进行了检测。观测到降雨期间屋顶径流中的铜浓度在200至11,000微克/升之间。屋顶的覆盖材料和排水系统是屋顶径流中高浓度铜的成因。很明显,朝向风向的屋顶面降雨量更大,因此产生的铜径流率更高。截留设施在去除铜方面的性能高达97%。