Abstract

Aspergillus spp. and other moulds cause life-threatening opportunistic infections in immunocompromised patients. Indoor contamination and construction work that liberate fungal spores are a major source of nosocomial aspergillosis. Dijon hospital is a tertiary care institution in northeast France undergoing construction work beside high-risk clinical units. To determine the impact of this activity, a surveillance programme was implemented one year before building work began in order to establish baseline levels of contamination. Air and surface fungal contamination in adult and paediatric haematology units were prospectively examined following use, or not, of a new air-treatment system with mobile Plasmair units (Airinspace). There were significant reductions in overall fungal contamination for the Plasmair treated rooms for air and surface samples in both clinical units. Plasmair treatment also significantly reduced A. fumigatus in the air. These data suggest that Plasmair units may provide an efficient method of reducing indoor fungal contamination in hospitals.

摘要

曲霉属及其他霉菌可在免疫功能低下的患者中引发危及生命的机会性感染。室内污染以及释放真菌孢子的建筑施工是医院获得性曲霉病的主要来源。第戎医院是法国东北部的一家三级医疗机构,在高危临床科室旁正在进行建筑施工。为确定此项活动的影响,在建筑工程开始前一年实施了一项监测计划,以确定污染的基线水平。在使用或未使用配备移动等离子体装置(Airinspace)的新型空气处理系统后,对成人和儿科血液科的空气和表面真菌污染情况进行了前瞻性检查。在两个临床科室中,经等离子体处理的房间的空气和表面样本的总体真菌污染均有显著降低。等离子体处理还显著减少了空气中的烟曲霉。这些数据表明,等离子体装置可能为减少医院室内真菌污染提供一种有效的方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验